2007
DOI: 10.1016/j.jchromb.2007.10.031
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of 3-nitrotyrosine, tyrosine, hydroxyproline and proline in exhaled breath condensate by hydrophilic interaction liquid chromatography/electrospray ionization tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
27
0

Year Published

2008
2008
2017
2017

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 55 publications
(28 citation statements)
references
References 39 publications
(60 reference statements)
1
27
0
Order By: Relevance
“…Gessner et al (Gessner et al 2001) pointed out that proteins may be a suitable reference substance to correct for dilution eVects. However, according to our previous investigations (Conventz et al 2007), non-volatile substances like amino acids are well suited to correct for the degree of dilution of the lining Xuid in the collected EBCs. Consequently, we chose to determine the amino acids tyrosine and proline (which are the biochemical precursors of 3-nitrotyrosine and trans-hydroxyproline) as "internal standards" to normalize for all measured biomarker concentrations.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Gessner et al (Gessner et al 2001) pointed out that proteins may be a suitable reference substance to correct for dilution eVects. However, according to our previous investigations (Conventz et al 2007), non-volatile substances like amino acids are well suited to correct for the degree of dilution of the lining Xuid in the collected EBCs. Consequently, we chose to determine the amino acids tyrosine and proline (which are the biochemical precursors of 3-nitrotyrosine and trans-hydroxyproline) as "internal standards" to normalize for all measured biomarker concentrations.…”
Section: Discussionmentioning
confidence: 99%
“…Simultaneous measurement of 3-nitrotyrosine, tyrosine, hydroxyproline and proline in EBC was undertaken according to our previous publication (Conventz et al 2007). In brief, 1 ml of EBC was freeze-dried and reconstituted in 50 l of HILIC eluent for concentration purposes.…”
Section: Chemical Analysis Of Biomarkers In Ebcmentioning
confidence: 99%
“…The use of metabolomics, proteomics and new modes of spectrometry further facilitate exhaled biomarker research [101][102][103][104][105][106][107][108][109][110][111][112][113]. Metabolomic pattern determined by using nuclear magnetic resonance measurements in EBC has been shown to discriminate between healthy and asthmatic children [111].…”
Section: Future Developments In Breath Testingmentioning
confidence: 99%
“…HILIC mode chromatography is important for the separation of highly polar substances such as un-derivatised amino acids [35][36][37] and the method is widely used in different fields including pharmaceutical, food science, environmental analysis and biomolecular research [38][39][40][41][42]. Moreover, there has been an increasing interest in HILIC since the 1980 s due to the use of low aqueous/high polar organic solvent mobile phase which are particularly suitable for ESI/MS detection as it results in increased sensitivity [43].…”
Section: Instrumental Performancementioning
confidence: 99%