Simultaneous Determination of 1,4‐Benzodiazepines and Tricyclic Antidepressants in Saliva after Sequential SPE Elution by the Same HPLC Conditions

Abstract: A new method has been described to determine both benzodiazepines (six) and tricyclic antidepressants (four) simultaneously in saliva by HPLC with a UV detector set at 240 nm using cholchicine as the internal standard. A careful specific sequential solid-phase elution was optimized and performed to elute benzodiazepines using a mixture of methanol-acetonitrile (1:1 v/v) followed by the elution of tricyclic antidepressants with methanol. Separation of the compounds was performed on a Kromasil column (250 × 4 mm… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 22 publications
0
4
0
Order By: Relevance
“…However, other biological matrices that is, saliva, dried blood spot, sweat, tear, cerebrospinal fluid, and hair have been employed as well. [6][7][8] Saliva as an alternative matrix for TDM, offers considerable benefits over serum, (a) salivary drug concentration indicates the unbound drug concentration in serum, (b) saliva sampling is a simple, noninvasive and inexpensive procedure which allows us to have repeated sampling. Patient can do the collection on his/her own.…”
Section: Introductionmentioning
confidence: 99%
“…However, other biological matrices that is, saliva, dried blood spot, sweat, tear, cerebrospinal fluid, and hair have been employed as well. [6][7][8] Saliva as an alternative matrix for TDM, offers considerable benefits over serum, (a) salivary drug concentration indicates the unbound drug concentration in serum, (b) saliva sampling is a simple, noninvasive and inexpensive procedure which allows us to have repeated sampling. Patient can do the collection on his/her own.…”
Section: Introductionmentioning
confidence: 99%
“…There was no obvious preference for choice of column, except for reversed-phase C 18 [55] or C 8 , [56] which was more prevalent than the alternative phases. Monolithic columns [57], consisting of continuous beds with through pores of organic or inorganic matrix, have found increasing applications for HPLC separations.…”
Section: High Performance Liquid Chromatography (Hplc)mentioning
confidence: 92%
“…The method was proved to be suitable for use both in clinical analysis, as well as for quality control of pharmaceutical formulations [64,65]. The analytes and the internal standard were extracted by Nexus (Varian) SPE cartridge and separated by 15 min, utilizing a Kromasil C 8 (150 × 4.6 mm; 5 mm) column with a gradient mobile phase containing methanol, acetonitrile, and 0.05 M ammonium acetate, delivered at a flow rate of 1.0 mL/min.…”
Section: Hplc Analysis Of Tricyclic Antidepressants Recent Advances Imentioning
confidence: 99%