2010
DOI: 10.1186/1477-3155-8-27
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous detection of Human Immunodeficiency Virus 1 and Hepatitis B virus infections using a dual-label time-resolved fluorometric assay

Abstract: A highly specific and novel dual-label time-resolved immunofluorometric assay was developed exploiting the unique emission wavelengths of the intrinsically fluorescent terbium (Tb3+) and europium (Eu3+) tracers for the simultaneous detection of human immunodeficiency virus 1 (HIV-1) and hepatitis B virus (HBV) infections, respectively. HIV-1 infection was detected using a double antigen sandwich format wherein anti-HIV-1 antibodies were captured using an in vivo biotinylated version of a chimeric HIV-1 antigen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0
1

Year Published

2011
2011
2019
2019

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 16 publications
(10 citation statements)
references
References 9 publications
0
8
0
1
Order By: Relevance
“…)T4–BSA–BTBCT 23 –Eu5.8 nmol L −1 [42]T4 (comp. )T4–BSA–B, SA–BCTOT–Eu6.7 nmol L −1 [40]Nanoparticle-basedPSASA-coated Eu(β-NTA) 3 -doped polystyrene NPs1.6 ng L −1 4[56]PSAIgG-coated Eu(β-NTA) 3 -doped polystyrene NPs0.21 ng L −1 4[57]AdenovirusIgG-coated Eu(β-NTA) 3 -doped polystyrene NPs5650000 virus particles L −1 4[58]Hepatitis B surface antigen (HBsAg)IgG-coated Eu(β-NTA) 3 -doped polystyrene NPs28 ng L −1 4[59] Listeria spp.IgG-coated Eu(β-NTA) 3 -doped polystyrene NPs20000 CFU L −1 4[60]Anthrax PASA-coated polystyrene NPs, biotinylated anti-SA, SA–Eu10 ng L −1 4[61]Hepatitis B surface antigen (HBsAg)F(ab) 2 -coated Eu(β-NTA) 3 -doped polystyrene NPs0.013 ng L −1 4[62]Anti-HIV-1 IgGPyridine-based Tb chelate-labeled HIV-1 antigenn.d.Enzyme-amplified lanthanide luminescenceα-fetoproteinIgG–ALP1.4 ng L −1 >2[67]Salicylphosphate/salicylic acid/Tb–EDTAα-fetoproteinBt–pAb/SA–ALP0.15 ng L −1 >2[68]5-fluorosalicyl phosphate/5-fluorosalicylic acid/Tb–EDTAα-fetoproteinIgG–ALP3 ng L −1 >2[66]Diflunisal phosphate/diflunisal/Tb–EDTAInterleukin 6SA–ALP0.5 ng L −1 (serum)[69]Diflunisal phosphate/diflunisal/Tb–EDTAPSASA–ALP2 ng L −1 [70]Diflunisal phosphate/diflunisal/Tb–EDTA10 ng L −1 (serum)comp. = c...…”
Section: Microtitre Plate-based Assaysmentioning
confidence: 99%
“…)T4–BSA–BTBCT 23 –Eu5.8 nmol L −1 [42]T4 (comp. )T4–BSA–B, SA–BCTOT–Eu6.7 nmol L −1 [40]Nanoparticle-basedPSASA-coated Eu(β-NTA) 3 -doped polystyrene NPs1.6 ng L −1 4[56]PSAIgG-coated Eu(β-NTA) 3 -doped polystyrene NPs0.21 ng L −1 4[57]AdenovirusIgG-coated Eu(β-NTA) 3 -doped polystyrene NPs5650000 virus particles L −1 4[58]Hepatitis B surface antigen (HBsAg)IgG-coated Eu(β-NTA) 3 -doped polystyrene NPs28 ng L −1 4[59] Listeria spp.IgG-coated Eu(β-NTA) 3 -doped polystyrene NPs20000 CFU L −1 4[60]Anthrax PASA-coated polystyrene NPs, biotinylated anti-SA, SA–Eu10 ng L −1 4[61]Hepatitis B surface antigen (HBsAg)F(ab) 2 -coated Eu(β-NTA) 3 -doped polystyrene NPs0.013 ng L −1 4[62]Anti-HIV-1 IgGPyridine-based Tb chelate-labeled HIV-1 antigenn.d.Enzyme-amplified lanthanide luminescenceα-fetoproteinIgG–ALP1.4 ng L −1 >2[67]Salicylphosphate/salicylic acid/Tb–EDTAα-fetoproteinBt–pAb/SA–ALP0.15 ng L −1 >2[68]5-fluorosalicyl phosphate/5-fluorosalicylic acid/Tb–EDTAα-fetoproteinIgG–ALP3 ng L −1 >2[66]Diflunisal phosphate/diflunisal/Tb–EDTAInterleukin 6SA–ALP0.5 ng L −1 (serum)[69]Diflunisal phosphate/diflunisal/Tb–EDTAPSASA–ALP2 ng L −1 [70]Diflunisal phosphate/diflunisal/Tb–EDTA10 ng L −1 (serum)comp. = c...…”
Section: Microtitre Plate-based Assaysmentioning
confidence: 99%
“…Terbium is an excellent lanthanide in view of multiplexing as it has evenly spread emission bands along the emission spectrum (compared to, for example, europium), enabling the use of multiple acceptors in an energy transfer application (Kokko et al, 2009;Mathis and Bazin, 2011). To name just a few examples, multiplexing has been applied to the simultaneous detection of human immunodeficiency virus and hepatitis B virus infections using Tb 3+ -and Eu 3+ -chelates (Myyryläinen et al, 2010), to the simultaneous detection of three model analytes (prostate-specific antigen, thyroid-stimulating hormone, and luteinizing hormone) using UCP reporters in a microarray format (Päkkilä et al, 2012), and to an ultrasensitive lung cancer immunoassay in human serum using a commercial luminescent terbium complex (Geissler et al, 2012).…”
Section: Future Trendsmentioning
confidence: 99%
“…Для такого обследования может быть особо востребована мультиплексная тест-система, обеспечивающая надежное, оперативное и недорогое тестирование [3,8,10]. Попытки создания таких систем включали: микрожидкостные устройства [8]; иммунохроматографические системы с боковым потоком [4]; флюориметрический анализ с двойными метками [9]; суспензионные иммуночипы [15]; микроматрицы, напечатанные на поверхности дна ячеек микротитровального планшета [13]; а также иммуноочипы на плоских слайдах [3]. Однако применение большинства из перечисленных тестов в клинической диагности-ке остается проблематичным из-за сложности процессов их изготовления, значительных затрат и необходимости использования сложных устройств [5,6,10,14].…”
Section: Introductionunclassified