2016
DOI: 10.1016/j.jelechem.2016.09.023
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous and sensitive detection of acetaminophen and valacyclovir based on two dimensional graphene nanosheets

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
15
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 44 publications
(16 citation statements)
references
References 51 publications
1
15
0
Order By: Relevance
“…The limit of detection (LOD) was further calculated to be 0.018 µM using the formula 3 σ/s , where σ denotes the standard deviation of three blank measurements and s represents the slope calculated from the calibration plot. The two calibration plots acquired in this study were similar to studies that involved the measurement of molecules, such as acetaminophen and valacyclovir, ascorbic acid, dopamine, uric acid, and NADH [25,59,71,72]. This observation might be explained based on the mechanism of the inner-sphere electrode reaction [25,73].…”
Section: Resultssupporting
confidence: 72%
See 2 more Smart Citations
“…The limit of detection (LOD) was further calculated to be 0.018 µM using the formula 3 σ/s , where σ denotes the standard deviation of three blank measurements and s represents the slope calculated from the calibration plot. The two calibration plots acquired in this study were similar to studies that involved the measurement of molecules, such as acetaminophen and valacyclovir, ascorbic acid, dopamine, uric acid, and NADH [25,59,71,72]. This observation might be explained based on the mechanism of the inner-sphere electrode reaction [25,73].…”
Section: Resultssupporting
confidence: 72%
“…The two calibration plots acquired in this study were similar to studies that involved the measurement of molecules, such as acetaminophen and valacyclovir, ascorbic acid, dopamine, uric acid, and NADH [25,59,71,72]. This observation might be explained based on the mechanism of the inner-sphere electrode reaction [25,73]. Important attributes such as the novelty analytical advantages and capabilities (e.g., linear range and LOD) of the developed F-GO/GCE electrochemical sensor were confirmed by comparing the performance of the CA sensors formerly reported in the literature as shown in Table 1.…”
Section: Resultsmentioning
confidence: 59%
See 1 more Smart Citation
“…Apart from direct interactions with the virus, functionalized graphene is also used as a biosensor for the detection and diagnosis of viruses, as well as producing other therapeutics [96][97][98]. The remarkable specific surface area enables the manipulation of electrical properties of the single biomolecule which, in turn, could achieve single-molecule detection for viral infection [99].…”
Section: Graphenementioning
confidence: 99%
“…Despite the fact that these methods are sensitive in detection, they tend to be complicated, time‐consuming, and usually require specialized and expensive instruments. On the contrary, electrochemical techniques have been highly considered as a good alternative because of their simplicity, good stability, cheap but fast response, excellent sensitivity and selectivity [12]. For this reason, electrochemical techniques have been considered as a simple but powerful tool for either individual or simultaneous detections.…”
Section: Introductionmentioning
confidence: 99%