1976
DOI: 10.1002/jps.2600650738
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous analysis of hydrocortisone and hydrocortisone phosphate by high‐pressure liquid chromatography: Reversed‐phase, ion‐pairing approach

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
5
0

Year Published

1978
1978
2014
2014

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 35 publications
(5 citation statements)
references
References 1 publication
(1 reference statement)
0
5
0
Order By: Relevance
“…The carboxylic acids can also be chromatographed as ion pairs with organic cations. Studies were made in the pH range [6][7][8] with symmetrical quaternary ammonium ions as counterions in the mobile phase.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The carboxylic acids can also be chromatographed as ion pairs with organic cations. Studies were made in the pH range [6][7][8] with symmetrical quaternary ammonium ions as counterions in the mobile phase.…”
Section: Resultsmentioning
confidence: 99%
“…Naphthalene acetic acid derivatives have been separated as ion pairs and as acids in reversed phase chromatographic systems using aqueous mobile phases containing methanol or acetonitrile (5). Separation of anionic solutes by similar systems after addition of quaternary ammonium compounds such as tetrapropylammonium, tetrabutylammonium, or tetrapentylammonium (6, 7) or cetrimide (8) has been reported. This paper reports on reversed phase chromatographic systems for separation of carboxylic acids in acidic form and as ion pairs using acetonitrile as organic component in the mobile phase and LiChrosorb RP-8 (10-µ particles) as hydrophobic solid phase.…”
mentioning
confidence: 99%
“…Phenothiazine" 15. Methoxyphenamine• (HC1) 16. Diphenhydramine• (HC1) 17. Diphenylpyraline-(HC1) 18. Dimethoxanate•(HC1) 19. Promethazine•(HC1) 20 Predicting Separation Conditions.…”
Section: Methodsmentioning
confidence: 99%
“…High efficiency ion-pair partition chromatography of amines has been demonstrated using aqueous (11)(12)(13) and nonaqueous (11) stationary liquid phases supported on silica gel. Recently, octadecylsilyl bonded packings have been used as stationary phases for reverse-phase "ion pair" chromatography of cationic sample components using a large organic anion as the counterion (14,15), and for anionic sample components using quaternary ammonium counterions (15)(16)(17)(18). Horvath et al (19,20) have investigated the retention of charged species from 0003-2700/78/0350-0491$01.00/0 aqueous solutions on octadecylsilyl phases and interpreted the results in terms of "solvophobic theory".…”
mentioning
confidence: 99%
“…It is used for treating various inflammatory conditions, lymphomas and for inducing precocious fetal lung maturation in threatened preterm labor. Several methods have been described for simultaneously determining hydrocortisone and some synthetic corticosteroids by high-performance liquid chromatography [8][9][10][11][12][13]. The goal of this study was to develop a method for the simultaneous analysis of fusidic acid and steroids from bulk drugs and human plasma, as they have same formulation, and there is no reported method for the determination of all these steroids and fusidic acid.…”
Section: Introductionmentioning
confidence: 99%