1993
DOI: 10.1016/0003-2670(93)80180-s
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous adsorptive stripping voltammetric determination of riboflavin and folic acid in multivitamin preparations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

1
15
0

Year Published

1995
1995
2019
2019

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 35 publications
(16 citation statements)
references
References 15 publications
1
15
0
Order By: Relevance
“…The results obtained are presented in Table 1. The results obtained for both formulations are in agreement with those values reported by the producers and those obtained by other voltammetric procedure [6]. On the basis of the obtained results it can be stated that the proposed procedure can be applied to folic acid determination in pharmaceutical formulations.…”
supporting
confidence: 93%
“…The results obtained are presented in Table 1. The results obtained for both formulations are in agreement with those values reported by the producers and those obtained by other voltammetric procedure [6]. On the basis of the obtained results it can be stated that the proposed procedure can be applied to folic acid determination in pharmaceutical formulations.…”
supporting
confidence: 93%
“…Adsorptive stripping voltammetry (ASV) on a Hanging mercury drop electrode (HMDE) has been successfully applied to the determination of low concentrations of riboflavin (vitamin B,) [1,2]. Mercury film electrodes (MFEs) have been recently applied to the determination of various organic compounds of biological and pharmaceutical significance [3-71.…”
Section: Introductionmentioning
confidence: 99%
“…8 acid [16], gold nanoparticles-modified carbon paste electrode (AuNPs/CPE) [17], ethynylferrocene modified carbon nanotubes paste electrode [18], carbon nanotube paste electrode (PBDCNPE) with 2,2'-[1,2-phenylenediylbis(nitrilomethylidene)]bis(4-hydroxyphenol) [19]. The detection limits obtained in these studies were in the level of 10 À6 to 10 À9 mol L À1 and sometimes the fabrication process associated with chemical modified electrodes is typically both time-consuming and laborious.…”
Section: Introductionmentioning
confidence: 97%
“…However, some electroanalytical methodologies were already developed for FA analysis in pharmaceutical formulations using dropping mercury electrodes (DME) [5], static mercury drop electrode (SMDE) [6][7][8], and in estuary water using hanging drop mercury electrode (HDME) [9].…”
Section: Introductionmentioning
confidence: 99%