2011
DOI: 10.1016/j.nima.2011.01.141
|View full text |Cite
|
Sign up to set email alerts
|

Simulation for CZT Compton PET (Maximization of the efficiency for PET using Compton event)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(7 citation statements)
references
References 2 publications
0
7
0
Order By: Relevance
“…After performing the simulation, six scenarios using different energy resolution (1%, 4%, and 6% FWHM at 511 keV) and spatial resolution (0.5 × 0.5 × 0.5 mm 3 , 1 × 1 × 1 mm 3 , 1 × 3 × 0.5 mm 3 , 1 × 3 × 1 mm 3 , and 1 × 5 × 1 mm 3 ) were considered based on previous published studies [11], [19], [23]- [25]. Table II summarizes the scenarios considered in post-processing for each system.…”
Section: Methods and Materials A Simulation Setupmentioning
confidence: 99%
See 1 more Smart Citation
“…After performing the simulation, six scenarios using different energy resolution (1%, 4%, and 6% FWHM at 511 keV) and spatial resolution (0.5 × 0.5 × 0.5 mm 3 , 1 × 1 × 1 mm 3 , 1 × 3 × 0.5 mm 3 , 1 × 3 × 1 mm 3 , and 1 × 5 × 1 mm 3 ) were considered based on previous published studies [11], [19], [23]- [25]. Table II summarizes the scenarios considered in post-processing for each system.…”
Section: Methods and Materials A Simulation Setupmentioning
confidence: 99%
“…where A and B are the vectors of the incident and scattered photons, respectively, calculated by the position information of detected events. Yoon et al [19] investigated the angular uncertainty due to effects of Doppler broadening, pixelization effect, and energy broadening with a CZT-based PET system. The energy resolution and spatial resolution of the system was 1% and 1 × 0.5 × 2.5 mm 3 , respectively.…”
Section: Introductionmentioning
confidence: 99%
“…17 Another attractive and novel strategy to increase system sensitivity is Compton PET concept, which uses the kinematics of Compton scattering to recover scattered photons concerning the direction of entry of photons. 98,99 Similar to true events, the recovered scattered photons could then be used within the reconstruction process to boost the signal-tonoise ratio further. This could be achieved through CZT detectors with high energy and positioning resolution.…”
Section: Sensitivitymentioning
confidence: 99%
“…Therefore, we selected only the single-pixel photopeak events of pixelated CdZnTe detectors from the individual CdZnTe pixels. experiments for prototype conventional PET systems using CdZnTe detectors [14,15]. However, few studies have focused on simulating a PET insert system [16].…”
Section: Small-animal Pet Configurations and Monte Carlo Simulationsmentioning
confidence: 99%
“…Monte Carlo (MC) simulation offers a cost-effective and useful method to understand the imaging ability of a PET based on a pixelated CdZnTe detector [13]. Many studies have reported aspects of both simulations and experiments for prototype conventional PET systems using CdZnTe detectors [14,15]. However, few studies have focused on simulating a PET insert system [16].…”
Section: Introductionmentioning
confidence: 99%