Simplified analysis of mid‐story seismically isolated buildings

Abstract: The mid-story isolation design method is recently gaining popularity for the seismic protective design of buildings located in the areas of high population. In a mid-story isolated building, the isolation system is incorporated into the mid-story rather than the base of the building. In this paper, the dynamic characteristics and seismic responses of mid-story isolated buildings are investigated using a simplified three-lumpedmass structural model for which equivalent linear properties are formulated. From the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

2
49
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 55 publications
(55 citation statements)
references
References 14 publications
2
49
0
Order By: Relevance
“…Tsuneki et al [1], Tasaka et al [2] and Murakami et al [3] discuss some building designs that incorporate the midstory isolation systems in Japan and its impact on structural response. Several numerical as well as experimental studies [3][4][5][6][7][8]16,17] analyzing the effectiveness and limitations of such isolation systems have also appeared. The effect of nonlinearity of the system (Shirayama, et al [4]; Hu et al [5]), the impact of the placement of isolators at different story levels and other isolator parameters on the isolation effectiveness (Huang, et al., [6]; Zhou et al [7]) and the effect of modal coupling on response amplification of isolated upper structure (Kobayashi and Koh 8) have been reported.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Tsuneki et al [1], Tasaka et al [2] and Murakami et al [3] discuss some building designs that incorporate the midstory isolation systems in Japan and its impact on structural response. Several numerical as well as experimental studies [3][4][5][6][7][8]16,17] analyzing the effectiveness and limitations of such isolation systems have also appeared. The effect of nonlinearity of the system (Shirayama, et al [4]; Hu et al [5]), the impact of the placement of isolators at different story levels and other isolator parameters on the isolation effectiveness (Huang, et al., [6]; Zhou et al [7]) and the effect of modal coupling on response amplification of isolated upper structure (Kobayashi and Koh 8) have been reported.…”
Section: Introductionmentioning
confidence: 99%
“…In a mid-story isolation system, this flexible representation of the upper part leads to a three-lumped mass model. Such three-lumped mass models have been used by Kobayashi and Koh [8] and Wang et al [17], to study the impact of modal interaction on the lower substructure and isolated superstructure response. In fact Wang et al [17] have used such a model to identify the range of sub and super structure frequencies where modal interaction can adversely affect the performance of the isolation system.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition, a mid-storey-isolation system [1][2][3][4][5][6][7][8][9] has been devised, and there exist practical examples. However, a design scheme which considers both structural deformation and acceleration response has not been proposed so far.…”
Section: Introductionmentioning
confidence: 99%
“…More importantly, it can enhance the construction feasibility in highly populated areas where installing an isolation system beneath the base of a building can be extremely difficult if the building separation and property line are particular concerns. The effectiveness has been proven regarding midstory isolation's role in reducing seismic demand on the superstructure above the isolation system subject to far-field ground motion [4][5][6][7].…”
Section: Introductionmentioning
confidence: 99%