Simple geometrical modifications for substantial color intensity and detection limit enhancements in lateral-flow immunochromatographic assays

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(7 citation statements)
references
References 45 publications
0
6
0
1
Order By: Relevance
“…Several fabrication methods have been proposed to modify the strip to reduce the flow rate in the LFA strip. The geometrical modifications of the LFA strips can be achieved by cutting the LFA strip into specific shapes [18,19] or using laser patterned photopolymer to create a barrier on nitrocellulose (NC) membrane [20] to control the flow rates in the LFA strips. Additionally, flow-interrupting materials can be inserted or embedded in the LFA strip to reduce the flow rate [21].…”
Section: Introductionmentioning
confidence: 99%
“…Several fabrication methods have been proposed to modify the strip to reduce the flow rate in the LFA strip. The geometrical modifications of the LFA strips can be achieved by cutting the LFA strip into specific shapes [18,19] or using laser patterned photopolymer to create a barrier on nitrocellulose (NC) membrane [20] to control the flow rates in the LFA strips. Additionally, flow-interrupting materials can be inserted or embedded in the LFA strip to reduce the flow rate [21].…”
Section: Introductionmentioning
confidence: 99%
“…4C) [30]. In the same line, recent works demonstrated that by decreasing the detection pad width and increasing the distance between the conjugate and the detection pads, a 2-fold better sensitivity is reached [32]. However, modification of the detection pad architecture is an amplification strategy limited by the compromise between the amplification pursuit and the compatibility with the available cartridge holders and strip readers.…”
Section: General Design/architecturementioning
confidence: 99%
“…Narrowing-width pads, where the wicking velocity is higher than normal strips, reduce the LOD by half, to 5 mIU/mL, whereas widening the detection pad might achieve color intensity of up to 150%. An optimal distance from the conjugate pad to the test line augments the highest possible color intensity by up to four times [ 184 ]. A physical–chemical coupling method using dissoluble saline barriers was developed to enhance LFA sensitivity.…”
Section: Pads Engineering-based Signal Amplificationmentioning