2010
DOI: 10.1016/j.apradiso.2009.08.009
|View full text |Cite
|
Sign up to set email alerts
|

Simple determination of 99Tc in radioactive waste using Tc extraction disk and imaging plates

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
6
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(6 citation statements)
references
References 12 publications
0
6
0
Order By: Relevance
“…Beta-particle-emitting nuclides 90 Sr and 3 H and alpha-particle-emitting nuclides 238 Pu, 239 Pu, 241 Am, and 244 Cm were analyzed using the conventional method described in previous reports [9][10][11][12][13][14][15][16]. For the gamma-ray-emitting nuclides 60 Co, 94 Nb, 152 Eu, and 154 Eu and beta-particle-emitting nuclides 14 C, 129 I, 36 Cl, 79 Se, and 99 Tc, the procedure was modified from the conventional method.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Beta-particle-emitting nuclides 90 Sr and 3 H and alpha-particle-emitting nuclides 238 Pu, 239 Pu, 241 Am, and 244 Cm were analyzed using the conventional method described in previous reports [9][10][11][12][13][14][15][16]. For the gamma-ray-emitting nuclides 60 Co, 94 Nb, 152 Eu, and 154 Eu and beta-particle-emitting nuclides 14 C, 129 I, 36 Cl, 79 Se, and 99 Tc, the procedure was modified from the conventional method.…”
Section: Methodsmentioning
confidence: 99%
“…The Re in the Tc-eluted solution was measured using inductively coupled plasma atomic emission spectroscopy (Shimadzu Co., ICPS-7510) to determine the chemical yield of Tc. Because there is no stable Tc isotope, the recovery was determined using Re, which behaves in the same manner as Tc [15]. After the Tc-eluted solution was made an addition to Aquasol-2 (PerkinElmer, Inc.), 99 Tc was measured using a liquid scintillation counter (LSC, PerkinElmer, Inc., TriCarb 2910LL).…”
Section: Analysis Of 79 Se and 99 Tcmentioning
confidence: 99%
See 1 more Smart Citation
“…Tc is a pure b À emitter, which can be measured by radiation counting. There are several analytical methods for Tc determination with extremely low limits of detection, like inductively coupled plasma mass spectrometry (ICP-MS), [1][2][3][4][5][6] radiochemical analysis methods, 7,8 total reection X-ray uorescence, 9 and so on. K. L. Shi et al 10 reviewed the studies on the determination of 99 Tc in environmental samples.…”
mentioning
confidence: 99%
“…( 3 H,14 C, 36 Cl, 41 Ca, 60 Co, 59,63 Ni, 90 Sr, 94 Nb, 99 Tc, 108m Ag, 129 I, 133 Ba, 137 Cs, 152,154 Eu, 166m Ho, 234,235,238 U, 238,239,240,242 Pu, 241,243 Am, 242,244 Cm)とし 非破壊 g 線測定法( 94 Nb, 108m Ag, 133 Ba, 152,154 Eu,…”
mentioning
confidence: 99%