Simple and fast method for the measurement of legacy and novel brominated flame retardants in human serum

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 17 publications
(3 citation statements)
references
References 34 publications
0
3
0
Order By: Relevance
“…Recently, there have been many studies involving the occurrence of several NBFRs in various environmental matrices, including air, , dusts, , sewage sludge, , and sediments, , as well as human serum. , It is worth noting that NBFRs have also been found in the Arctic, which indicates that these compounds can undergo a long-range atmospheric transport (LRAT), just as the restricted and banned traditional BFRs . Bioaccumulation potential and adverse effects of NBFRs have been documented, , which is worthy of attention because they may have the same properties as the restricted and banned BFRs, particularly considering their physical and chemical similarities to traditional BFRs.…”
Section: Introductionmentioning
confidence: 99%
“…Recently, there have been many studies involving the occurrence of several NBFRs in various environmental matrices, including air, , dusts, , sewage sludge, , and sediments, , as well as human serum. , It is worth noting that NBFRs have also been found in the Arctic, which indicates that these compounds can undergo a long-range atmospheric transport (LRAT), just as the restricted and banned traditional BFRs . Bioaccumulation potential and adverse effects of NBFRs have been documented, , which is worthy of attention because they may have the same properties as the restricted and banned BFRs, particularly considering their physical and chemical similarities to traditional BFRs.…”
Section: Introductionmentioning
confidence: 99%
“…Accuracy and precision were also determined through the data obtained with three series on independent days. The acceptance limits of the accuracy profiles were set at ±20% of the nominal concentrations, and the tolerance limit was set at 17.5% in accordance with the literature [ 32 , 33 ]. The tolerance limit was evaluated through the percentage of risk of having measurements fall outside of the acceptance limits for each level of concentration.…”
Section: Methodsmentioning
confidence: 99%
“…The methodology to quantify 8 polybrominated diphenylethers (PBDEs) (namely, BDE-28, -47, -99, -100, -153, -154, -183 and -209) has been described in Pirard and Charlier, 2018 [18]. In summary, serum sample, quality control sample, and standard calibration sample were denaturized with a glacial acetic acid/water mixture (3/7, v/v) and then extracted twice with a mixture of hexane and acetone (95/5, v/v).…”
Section: Analysis Of Bfrs In Serummentioning