Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2002
DOI: 10.1016/s0009-2614(02)00335-4
|View full text |Cite
|
Sign up to set email alerts
|

Simple and efficient decoupling in magic-angle spinning solid-state NMR: the XiX scheme

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
213
0
1

Year Published

2005
2005
2022
2022

Publication Types

Select...
5
5

Relationship

2
8

Authors

Journals

citations
Cited by 238 publications
(219 citation statements)
references
References 12 publications
5
213
0
1
Order By: Relevance
“…The experiments on dry CNC-1 were performed at a sample spinning frequency of 17 kHz utilizing a Varian 3.2 mm double-resonance probehead, whereas the experiments on the never-dried CNCS-1 and rehydrated CNC-1R1 and CNC-1R2 samples were done at MAS frequency of 4 kHz using a Varian 4 mm double-resonance probehead. Single contact ramped CP 19 experiments with a contact time of 0.8 ms were performed using proton decoupling with the help of the XiX sequence 20,21 during the detection of the 13 C NMR signal. We confirmed that the RAMP-CP spectra were quantitative by comparing them to multiple contact RAMP-CP experiments.…”
Section: ■ Experimental Sectionmentioning
confidence: 99%
“…The experiments on dry CNC-1 were performed at a sample spinning frequency of 17 kHz utilizing a Varian 3.2 mm double-resonance probehead, whereas the experiments on the never-dried CNCS-1 and rehydrated CNC-1R1 and CNC-1R2 samples were done at MAS frequency of 4 kHz using a Varian 4 mm double-resonance probehead. Single contact ramped CP 19 experiments with a contact time of 0.8 ms were performed using proton decoupling with the help of the XiX sequence 20,21 during the detection of the 13 C NMR signal. We confirmed that the RAMP-CP spectra were quantitative by comparing them to multiple contact RAMP-CP experiments.…”
Section: ■ Experimental Sectionmentioning
confidence: 99%
“…An adiabatic passage was used with a tangential shape on the proton channel with Δrf = 40 kHz and a contact time of 500 μs (Hediger et al 1995;Ernst and Meier 2010). During the acquisition, XiX proton decoupling was applied at a field strength of 100 kHz (Tekely et al 1994;Detken et al 2002). The 13 C homonuclear correlation experiments used the DREAM sequence (Verel et al 2001) with Δrf = 16 kHz.…”
Section: Spectroscopymentioning
confidence: 99%
“…Different efficient decoupling sequences 76,77 were applied to improve resolution, but they showed no improvement. Also higher spinning frequencies (>25 kHz) with or without decoupling did show no improvement as for instance observed for copper containing samples.…”
Section: Heteronuclear Mofsmentioning
confidence: 99%