2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century 2008
DOI: 10.1109/pes.2008.4596096
|View full text |Cite
|
Sign up to set email alerts
|

SIMEFAS: A phasor measurement system for the security and integrity of Mexico’s electric power system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2010
2010
2014
2014

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 4 publications
0
8
0
Order By: Relevance
“…Figure 1 shows a schematic diagram of the Mexican Interconnected System (MIS) showing the location of main regional centers and the distribution of data concentrators. At present, data are sent to 10 Phasor Data Concentrators (PDCs) for analysis, protection and control purposes [1].…”
Section: The Wams In the Mismentioning
confidence: 99%
See 2 more Smart Citations
“…Figure 1 shows a schematic diagram of the Mexican Interconnected System (MIS) showing the location of main regional centers and the distribution of data concentrators. At present, data are sent to 10 Phasor Data Concentrators (PDCs) for analysis, protection and control purposes [1].…”
Section: The Wams In the Mismentioning
confidence: 99%
“…The relatively sparse distribution of PMUs provides reliable coverage of system response with relatively high geographical resolution [1], [2]. Data gaps, the uneven distribution of the observations or sparse coverage, and differences in temporal resolution of dynamic recorders, among other factors, however, pose different kinds of difficulties that have to be addressed.…”
Section: The Wams In the Mismentioning
confidence: 99%
See 1 more Smart Citation
“…Other WAMS projects have been established in the past decade, including those in the U.S. Eastern Interconnection (EI) [17], Hydro Québec (Canada) [18], the SIMEFAS system in Mexico [19], China [20], [21], Brazil [22], Italy [23], the Nordic power systems [2], [24] and others. In the U.S. EI, WAMS has been successful in using PMUs for power system operations [12].…”
Section: A Wide-area Measurement Systemmentioning
confidence: 99%
“…A key element to achieve this goal is the wide area measurement system (WAMS), and more specifically the phasor measurement units (PMUs) or synchrophasors. Many PMUs have been installed in power systems around the world [3]- [7]. The PMUs were initially used for monitoring task, then were included in the area of protection, and recently are being incorporated in the control area.…”
Section: Introductionmentioning
confidence: 99%