Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
Encyclopedia of Magnetic Resonance 2011
DOI: 10.1002/9780470034590.emrstm0505.pub2
|View full text |Cite
|
Sign up to set email alerts
|

Silicon-29 NMR

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
3
1
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 77 publications
0
5
0
Order By: Relevance
“…Solid‐state 29 Si‐NMR evidences higher integration of a signal at −67 ppm in E_2.5 ( Figure b) compared to E_0.5 (Figure 3a). As this signal corresponds to R‐ Si (O) 3 building units, [ 20 ] it can be correlated to the concentration of cross‐linking points. Increased cross‐link concentration could be explained by a faster curing reaction of E_2.5.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Solid‐state 29 Si‐NMR evidences higher integration of a signal at −67 ppm in E_2.5 ( Figure b) compared to E_0.5 (Figure 3a). As this signal corresponds to R‐ Si (O) 3 building units, [ 20 ] it can be correlated to the concentration of cross‐linking points. Increased cross‐link concentration could be explained by a faster curing reaction of E_2.5.…”
Section: Resultsmentioning
confidence: 99%
“…Samples were aged for 14 days before the experiment. d) 29 Si solid‐state NMR of elastomer E_S14 (SSBs (−28 and −72 ppm), remaining  Si OH (−13 ppm),  Si (CH 2 ) 3  (−22 ppm), and R‐ Si (O) 3 building units (−67 ppm) [ 20 ] ).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Although they are not completely resolved, a rough estimate of the block lengths according to Eq. (25) gives an average length of about four Nylon 6 and four Nylon 6,6 units. In the copolymer produced from an equimolar monomer blend subjected to polycondensation for 8 h at 260°C (Figure14B), the average length of each block type is of about 2.0.…”
Section: Lsc Nmr In the Study Of Interchange Reactionsmentioning
confidence: 99%
“…The advantage of not polluting the sample is offset by an ineffective use of spectrometer time, which can be somewhat alleviated by using shorter pulses (40") and shorter recovery times (20 s). (iii) Using population transfer pulse programs [25].…”
Section: Other Nuclei -"N and 20simentioning
confidence: 99%