Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2021
DOI: 10.1007/s00216-021-03251-5
|View full text |Cite
|
Sign up to set email alerts
|

Signal amplification strategies for clinical biomarker quantification using elemental mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(7 citation statements)
references
References 37 publications
0
7
0
Order By: Relevance
“…For more details about amplification strategies, the reader is referred elsewhere. 153 SC-ICP-MS shows a wide range of different applications. It allows for the quantification of the absolute amounts (masses) of endogenous and exogenous metal(loid)s, as well as of some important non-metals (e.g., P, S).…”
Section: Calculationsmentioning
confidence: 99%
“…For more details about amplification strategies, the reader is referred elsewhere. 153 SC-ICP-MS shows a wide range of different applications. It allows for the quantification of the absolute amounts (masses) of endogenous and exogenous metal(loid)s, as well as of some important non-metals (e.g., P, S).…”
Section: Calculationsmentioning
confidence: 99%
“…Element tagging for immunoassay readout with ICP-MS has gained popularity over recent years and methodological developments are summarised in two review articles. 9,11 Numerous immunoassay formats have been evaluated, primarily using REE and transition metals with various signal amplications strategies. While elemental MS detection can offer technological advantages for immunoassays in terms of LOD and multiplexing capability, instrumentation remains relatively complex compared to automated readout methods such as uorescence, chemiluminescence and electrochemiluminescence.…”
Section: Elements As Tags For Indirect Determinationsmentioning
confidence: 99%
“…Using rolling circular amplication, protein quantitation was achieved with higher sensitivity but smaller dynamic range than with Eu/Sm tagging. 11,179,181 Yin et al 182 used Mucin 1 (MUC1) from the human breast cancer cell line MCF-7 to model a multifunctional platform based on capture and release for non-destructive enumeration of circulating tumour cells (CTCs), thus allowing for subsequent molecular and functional readouts. Capture of MUC1 by capture probes (MUC1 specic aptamer hybridized to partially complementary strand (initiator) and immobilised on magnetic beads) caused release of initiator strands that were then hybridised to Tb labelled complementary strands (substrates) immobilised on detection probes.…”
Section: Elements As Tags For Indirect Determinationsmentioning
confidence: 99%
See 1 more Smart Citation
“…15,16 Moreover, specic standards are still required since the stoichiometry of the total probe concentration is hard to precisely determine. 17 As a solution, a standardfree strategy where the intrinsic proportion of biomarker subtypes can be revealed directly by the ratio of probe signals, attracts much attention. The construction of a stable data acquisitions and processing platform with unitary criteria is an ever-increasing demand.…”
Section: Introductionmentioning
confidence: 99%