Signal Amplification of FISH for Automated Detection Using Image Cytometry

Abstract: The purpose of this study was to improve the detection of FISH signals, in order that spot counting by a fully automated image cytometer be comparable to that obtained visually under the microscope. Two systems of spot scoring, visual and automated counting, were investigated in parallel on stimulated human lymphocytes with FISH using a biotinylated centromeric probe for chromosome 3. Signal characteristics were first analyzed on images recorded with a coupled charge device (CCD) camera. Number of spots per nu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
12
0

Year Published

1998
1998
2012
2012

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 12 publications
(12 citation statements)
references
References 10 publications
(14 reference statements)
0
12
0
Order By: Relevance
“…Correct detection of FISH signals is the greatest challenge of automated analysis, since signals demonstrate large variations regarding shape, size, and intensity (21). FISH signals were correctly counted by automated analysis in~69% of nuclei.…”
Section: Discussionmentioning
confidence: 99%
“…Correct detection of FISH signals is the greatest challenge of automated analysis, since signals demonstrate large variations regarding shape, size, and intensity (21). FISH signals were correctly counted by automated analysis in~69% of nuclei.…”
Section: Discussionmentioning
confidence: 99%
“…By the end of the 90s, the first attempt to analyze FISH-labeled tissue sections in 3D was also made by Adiga et al They quantified CEP7 signals in 10-15 lm thick tissue sections from patients with prostate cancer using confocal microscopy and semi-automated image analysis and reported results of automated counting being almost comparable with visual counting (21,33,80). In parallel with technological development, it has also been recognized that the quality of samples has huge effect on the performance of automated systems thus efforts with more or less success were taken in order to make the FISH spots brighter using various signal amplification methods (64). Apart from early technical comparative studies, results of automated analyses were almost always compared to that of manual scoring considering the latter one as a reference.…”
Section: Pioneering Agementioning
confidence: 99%
“…Cells were analyzed as described by Truong et al 16 First, DNA ploidy measurements were performed by exciting the DAPI at 330 nm, then Texas Red was excited with 577 nm red light for BrdU detection. Segmentation of both DAPI and Texas Red emitted light was performed by using an automatic threshold- ing procedure.…”
Section: Image Analysis and Data Processingmentioning
confidence: 99%
“…Still, systematic studies using image cytometry on fluorescence-stained samples are relatively few; most of them have analyzed specimen pretreatments and fixation procedures for one parameter only, such as in situ hybridization. 16 BrdU detection of proliferating cells is one of the most widely used methods because of its simple application and detection. Generally, there exists a good correlation between the BrdU labeling index (BLI) and breast carcinoma growth.…”
mentioning
confidence: 99%