2013
DOI: 10.1016/j.fusengdes.2013.04.011
|View full text |Cite
|
Sign up to set email alerts
|

Shutdown dose rate assessment for a DCLL blanket-based reactor: Application of the R2S-UNED approach

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2015
2015
2017
2017

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 18 publications
(6 citation statements)
references
References 9 publications
0
6
0
Order By: Relevance
“…The latest versions of R2Smesh [5], MCR2S [6], R2SUNED [7] and Advanced D1S [8] were applied to perform the shutdown dose rate calculations at the experimental positions. Both Advanced D1S and R2Smesh are based on the MCNP5 [4] and FISPACT 2007 [10] codes.…”
Section: Shutdown Dose Rate Calculationsmentioning
confidence: 99%
See 1 more Smart Citation
“…The latest versions of R2Smesh [5], MCR2S [6], R2SUNED [7] and Advanced D1S [8] were applied to perform the shutdown dose rate calculations at the experimental positions. Both Advanced D1S and R2Smesh are based on the MCNP5 [4] and FISPACT 2007 [10] codes.…”
Section: Shutdown Dose Rate Calculationsmentioning
confidence: 99%
“…The experimental data will be used to validate the European state-of-the-art computational tools for Shutdown Dose Rate (SDR) assessment used in ITER. Three different Rigorous-Two Step approaches (R2Smesh [5], MCR2S [6], and R2SUNED [7]) and a Direct-One Step tool (Advanced D1S [8]) based on MCNP Monte Carlo code will be employed in the benchmark analyses. The assessment of shutdown dose rate is a key issue for the design and maintenance operations of ITER components.…”
Section: Introductionmentioning
confidence: 99%
“…MCNP5.1.6 with MCPLIB05T photon data libraries were used for the decay photon transport analyses and computation of SDR field throughout the equatorial port interspace and tallies of interest. The whole computational cycle was automated by means of the R2S-UNED software [9]. ITER irradiation scenario SA2 and 10 6 s of cooling time, and ITER-standard dose conversion coefficient standards were employed [10,11].…”
Section: Computational Methodologymentioning
confidence: 99%
“…A summary of the SDR mapping tools currently existing in Europe is given in [2]. There is one based on directone-step (D1S) treatment [3] and three following the rigorous-two-step (R2S) coupling methodology [4], [5] and [6].…”
Section: Introductionmentioning
confidence: 99%