2016
DOI: 10.1016/j.fusengdes.2016.01.055
|View full text |Cite
|
Sign up to set email alerts
|

Neutronics experiments and analyses in preparation of DT operations at JET

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
10
0

Year Published

2016
2016
2018
2018

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 22 publications
(12 citation statements)
references
References 8 publications
1
10
0
Order By: Relevance
“…During the last decades, Rigorous Two-Step (R2S) [4][5][6] and Direct One-Step (D1S) [7] tools based on MCNP Monte Carlo code [8] have been developed and extensively applied for ITER assessment. The prediction capabilities of these tools have been verified through several computational and experimental benchmarks and in particular, SDR benchmark experiments have been conducted at JET since 2005 [2,[9][10][11]. The results of the past benchmark experiments confirmed that the available calculation methodologies for shutdown dose rate assessments were in good agreement and capable of reproducing the measured quantities in the examined temporal range in a tokamak configuration within the experimental uncertainty margin.…”
Section: Introductionmentioning
confidence: 81%
See 3 more Smart Citations
“…During the last decades, Rigorous Two-Step (R2S) [4][5][6] and Direct One-Step (D1S) [7] tools based on MCNP Monte Carlo code [8] have been developed and extensively applied for ITER assessment. The prediction capabilities of these tools have been verified through several computational and experimental benchmarks and in particular, SDR benchmark experiments have been conducted at JET since 2005 [2,[9][10][11]. The results of the past benchmark experiments confirmed that the available calculation methodologies for shutdown dose rate assessments were in good agreement and capable of reproducing the measured quantities in the examined temporal range in a tokamak configuration within the experimental uncertainty margin.…”
Section: Introductionmentioning
confidence: 81%
“…Shutdown dose rate was measured using commercial spherical air-vented ionization chambers (PTW type TM32002,  140 mm) procured by ENEA and KIT. These dosimeters were selected on the basis of the following requirements and operative conditions: low activation, large range of operation (from background to 30 mSv/h, according to pre-analysis), high efficiency, long term stability, flat energy and dose response, isotropic angular response, radiation resistance (up to 10 15 n/cm 2 total fluence), compact dimensions, remote control and acquisition and compliancy with JET regulation [2]. Before the installation at JET, accurate calibration under X and gamma sources and preliminary irradiation tests under DT neutrons at the Frascati Neutron Generator (FNG) were performed [12].…”
Section: Experimental Assembly Of Dd Experimentsmentioning
confidence: 99%
See 2 more Smart Citations
“…Improvement of the R2S scheme are planned: to accelerate the calculation (MENDEL parallelization), to propagate the statistical error of the first step and to handle different materials in a mesh-cell. Extended validation exercises will be carried out with the Frascati Neutron source Generator SDR experiment [11] and the JET SDR measurement [23]. TRIPOLI-4 ® R2S should be used in near-term for ITER neutronic analysis at CEA [24].…”
Section: Discussionmentioning
confidence: 99%