2018
DOI: 10.1016/j.scs.2018.07.002
|View full text |Cite
|
Sign up to set email alerts
|

Shunt active power filter: Current status of control techniques and its integration to renewable energy sources

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
23
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 68 publications
(23 citation statements)
references
References 102 publications
0
23
0
Order By: Relevance
“…This, however, has resulted in poor convergence performance. [11] In the time domain, many methods have been proposed for reference generation. A DC-link voltage based control has been employed in [12] not only to compensate the DC-link voltage but also to enhance the steady-state performance of the SAPF.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…This, however, has resulted in poor convergence performance. [11] In the time domain, many methods have been proposed for reference generation. A DC-link voltage based control has been employed in [12] not only to compensate the DC-link voltage but also to enhance the steady-state performance of the SAPF.…”
Section: Introductionmentioning
confidence: 99%
“…These methods offer a reduction in high-frequency ripple current. However, they present non-satisfactory performance during load variations [11]. In [14] a direct power controller with a switching table was applied as an alternative to the previous DC-link voltage oriented control.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…An APF is usually connected to the point of common coupling (PCC) in parallel or series to perform its designed functions; however, shunt APFs are more commonly used because they provide more flexible compensation functions though current-injecting control and require less auxiliary equipment. When a series APF and a shunt APF are connected with a common direct current (DC) link, they can be used simultaneously, known as a unified power quality conditioner (UPQC) [1][2][3][4].In open literature, there are a lot of papers investigating the application of APF to the mitigation of PQ issues, such as the improvement of PCC voltage stability [5,6], compensation of harmonic currents [5][6][7] and unbalance load currents [7,8], injection of active power [8,9], regulation of reactive power [6,9], etc. In order to develop high-performance APFs, it is crucial to improve the switching performance of power converters.…”
mentioning
confidence: 99%
“…An APF is usually connected to the point of common coupling (PCC) in parallel or series to perform its designed functions; however, shunt APFs are more commonly used because they provide more flexible compensation functions though current-injecting control and require less auxiliary equipment. When a series APF and a shunt APF are connected with a common direct current (DC) link, they can be used simultaneously, known as a unified power quality conditioner (UPQC) [1][2][3][4].…”
mentioning
confidence: 99%