Shear carrying capacity of Ultra-High Performance Concrete beams

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
16
0
2

Year Published

2009
2009
2023
2023

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 23 publications
(22 citation statements)
references
References 0 publications
2
16
0
2
Order By: Relevance
“…Thus, the negligible change in the bond strength obtained in this study might be due to the small differences between the prestressing forces, which were too small to provide any significant changes for the strands embedded in UHPFRC. In addition, to achieve the significant Hoyer effect required to improve the bond strength of the prestressing strands, a sufficient embedment length is required to transfer strand stress to the surrounding concrete (Hegger et al 2004). However, in this study, extremely short embedment lengths of 1d b and 2d b that resulted in a limited Hoyer effect were applied.…”
Section: Effect Of Initial Prestressing Forcementioning
confidence: 99%
See 1 more Smart Citation
“…Thus, the negligible change in the bond strength obtained in this study might be due to the small differences between the prestressing forces, which were too small to provide any significant changes for the strands embedded in UHPFRC. In addition, to achieve the significant Hoyer effect required to improve the bond strength of the prestressing strands, a sufficient embedment length is required to transfer strand stress to the surrounding concrete (Hegger et al 2004). However, in this study, extremely short embedment lengths of 1d b and 2d b that resulted in a limited Hoyer effect were applied.…”
Section: Effect Of Initial Prestressing Forcementioning
confidence: 99%
“…For example, the average bond strengths of round steel bars in UHPFRC were found to be 7.0, 6.2, and 5.4 MPa for the cases of 1d b , 1.5d b , and 2d b , respectively. Owing to their deformed shape, which was due to 7-wire twisting and a Hoyer effect at the live end (Hegger et al 2004), the strands achieved much higher bond strengths than the round steel bars. The diameter of the strand was initially reduced by Poisson's effect when a pretensioning was applied (before cutting the strand).…”
Section: Transfer Lengthmentioning
confidence: 99%
“…Das Sprengwerk, auch Druckbogen genannt, verläuft unmittelbar ins Auflager und muss dort mit der eingeleiteten Vorspannkraft im Gleichgewicht stehen [16]. Ist die Übertragungslänge der Litze größer als der Auflagerüberstand, unterstützt lediglich der über dem Auflager übertragene Anteil der Vorspannung das Sprengwerk [11], [12].…”
Section: Tragverhalten Und Bemessungunclassified
“…Für eine sichere und wirtschaftliche Bemessung ist ein auf UHPC abgestimmtes Verbundmodell erforderlich, das die spezifischen Einflüsse der Faserwirkung und der Betondeckung auf die Übertragungslänge erfasst. Die sichere Einleitung und Verankerung der Vorspannkraft ist für die Querkrafttragfähigkeit sowohl von Spannbetonbalken [4] als auch von Spannbetonhohlplatten [5,6] von entscheidender Bedeutung.…”
Section: Introductionunclassified