Severe catheter kinking and entrapment during transradial coronary angiography: Percutaneous retrieval using a sheathless guide catheter

Abstract: The transradial (TR) approach for coronary angiography and intervention is increasingly used worldwide because of several advantages such as reduced bleeding and vascular complications. During TR procedures, aggressive catheter manipulation in the setting of complex and tortuous arterial anatomy can lead to catheter kinking and entrapment. Several percutaneous retrieval techniques using either homolateral radial access or femoral access have been described previously. We demonstrate, for the first time, the us… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
5
1
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 4 publications
0
6
0
Order By: Relevance
“…In our case, the internal diameter of 6 French EBU guiding catheter was 1.8mm, which was bigger than the external diameter of 5 French angiography catheter, which was 1.7mm, and make sure that the guiding catheter can enclose the angiography catheter. According to Aminian's study [11] , the length of guiding catheter was between "Knotted point-Puncture point" distance and "Knotted point-Cut point" distance, and the length of exceeded-guiding catheter part of angiography catheter was too short to fix, so that we make balloon and angiography catheter contact tightly and as a result we prolong the length of exceeded-guiding catheter part of angiography catheter sufficiently in order to facilitate the procedure, which was a bright point of our case.…”
Section: Discussionmentioning
confidence: 99%
“…In our case, the internal diameter of 6 French EBU guiding catheter was 1.8mm, which was bigger than the external diameter of 5 French angiography catheter, which was 1.7mm, and make sure that the guiding catheter can enclose the angiography catheter. According to Aminian's study [11] , the length of guiding catheter was between "Knotted point-Puncture point" distance and "Knotted point-Cut point" distance, and the length of exceeded-guiding catheter part of angiography catheter was too short to fix, so that we make balloon and angiography catheter contact tightly and as a result we prolong the length of exceeded-guiding catheter part of angiography catheter sufficiently in order to facilitate the procedure, which was a bright point of our case.…”
Section: Discussionmentioning
confidence: 99%
“…Replacing the sheath with a larger and longer sheath and advancing it to the kinked segment of the catheter allows gently retracting the catheter into the larger sheath and its withdrawal. 24 Internal Fixation with femoral access and advancement of a 6Fr catheter into the innominate and snaring the proximal end of the kinked catheter fixates the catheter for untwisting at the wrist with gentle advancement of a 0.035″ hydrophilic wire through the catheter. 25 The detailed algorithm for managing a catheter kink is outlined in Fig.…”
Section: Access Challengesmentioning
confidence: 99%
“…Replacing the sheath with a larger and longer sheath and advancing it to the kinked segment of the catheter allows gently retracting the catheter into the larger sheath and its withdrawal. 24 …”
Section: Access Challengesmentioning
confidence: 99%
“…Pushing these large sheaths without their respective introducers directly over the trapped catheter could potentially risk trauma to the radial artery and stripping of the arterial intima. This technique has been described using long sheaths or sheathless guide catheters .…”
Section: Case Reportmentioning