Magnetic resonance direct thrombus imaging is an accurate noninvasive test for diagnosis of DVT, and its accuracy is maintained below the knee. Comparison of individual venous segments showed that results of MRDTI agreed strongly with findings on venography. Scanning was well tolerated, and interpretation was highly reproducible.
Longitudinal stent deformation can occur secondary to a variety of mechanisms and identification is important as, left untreated, it may be associated with a risk of stent thrombosis. Although seen with several different stents, in our series it was more commonly observed with the Promus Element stent.
Objective A meta-analysis of all randomised controlled studies that compare outcomes of transradial versus the transfemoral route to better define best practice in patients with ST elevation myocardial infarction (STEMI). Design A Medline and Embase search was conducted using the search terms 'transradial,' 'radial', 'STEMI', 'myocardial' and 'infarction'. Setting Randomised controlled studies that compare outcomes of transradial versus the transfemoral route. Patients A total of nine studies were identified that consisted of 2977 patients with STEMI. Interventions Studies that compare outcomes of transradial versus the transfemoral route. Main outcome measures The primary clinical outcomes of interest were (1) mortality; (2) major adverse cardiac events (MACE); (3) major bleeding and (4) access site complications. Results Transradial PCI was associated with a reduction in mortality (OR 0.53, 95% CI 0.33 to 0.84; p¼0.008), MACE (OR 0.62, 95% CI 0.43 to 0.90; p¼0.012), major bleeding events (OR 0.63, 95% CI 0.35-1.12; p¼0.12) and access site complications (OR 0.30, 95% CI 0.19 to 0.48; p<0.0001) compared with procedures performed through the femoral route. Conclusions This meta-analysis demonstrates a significant reduction in mortality, MACE and major access site complications associated with the transradial access site in STEMI. The meta-analysis supports the preferential use of radial access for STEMI PCI.
VESPA MR venography yielded MIP venograms that were highly accurate for the diagnosis of DVT in femoral and iliac veins. Interpretation of the studies was also highly reproducible.
Failure to deliver stents is one of the commonest causes of procedural failure in contemporary PCI practice. We describe successful use of the Guideliner catheter, the first purpose designed FDA and CE marked device delivery catheter in 13 complex cases in native coronary vessels and bypass grafts performed via the radial route to enable distal stent delivery following failure of conventional techniques. We discuss how the Guideliner catheter may be used to facilitate difficult radial cases.
In this large study, TRA is associated with reduced percutaneous coronary intervention-related complications in all patient groups and may reduce major adverse cardiac events and mortality in ACS patients. TRA is superior to transfemoral access with closure devices. Use of TRA may lead to important patient benefits in routine practice. TRA should be considered the preferred access site for percutaneous coronary intervention.
Use of the 6.5 Fr sheathless guide catheter system, which has an outer diameter <5 Fr sheath, as the default system in routine PCI is feasible with a high rate of procedural success via the radial artery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.