2019 IEEE 10th International Workshop on Applied Measurements for Power Systems (AMPS) 2019
DOI: 10.1109/amps.2019.8897759
|View full text |Cite
|
Sign up to set email alerts
|

Setup and Characterisation of Reference Current-to-Voltage Transformers for Wideband Current Transformers Calibration up to 2 kA

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 2 publications
0
5
0
Order By: Relevance
“…Among them, two phases are connected to the live line and the zero line to collect the characteristic value of circuit voltage. Connect it to the in-phase measurement port with the current transformer, and then the parameter information such as power and power factor can be calculated [15].…”
Section: Design Of Interface Board Of Voltage Transformermentioning
confidence: 99%
“…Among them, two phases are connected to the live line and the zero line to collect the characteristic value of circuit voltage. Connect it to the in-phase measurement port with the current transformer, and then the parameter information such as power and power factor can be calculated [15].…”
Section: Design Of Interface Board Of Voltage Transformermentioning
confidence: 99%
“…are needed when the output of the device under test (DUT) is a sampled value data stream (SVs). The synchronization signals can be obtained by GPS receivers and be transmitted as pulse per second (PPS), IEEE 1588-2008 (PTPv2) and inter-range instrumentation group B (IRIG-B) [12]. An example of generated current waveform is shown in Fig.…”
Section: Reference Systems For It Calibration 421 Reference Setup For...mentioning
confidence: 99%
“…The evaluation of the frequency response consists of three aspects: the error differences with different current ranges in use, the linearity of the CT at different primary currents and the burdening of the CT. Firstly, measurements of the frequency responses were carried out in the different current ranges of CT200. The CT200 was calibrated with the CT50 [6], which was calibrated before with a set of Fluke A40B [7] and now behaves as the reference. The measured frequency response i(f) and i(f) for the CT200 are displayed by the solid curves (#1 to #4) in Fig.…”
Section: B Characterization Of the C-to-v Transformersmentioning
confidence: 99%