2020 Conference on Precision Electromagnetic Measurements (CPEM) 2020
DOI: 10.1109/cpem49742.2020.9191814
|View full text |Cite
|
Sign up to set email alerts
|

Development of a Wideband Current-to-Voltage Transformer Set for Currents up to 2 kA

Abstract: This paper describes the setup and characterization of a set of wideband Current-to-Voltage (C-to-V) transformers equipped with symmetrical primary windings. The objective is to use the C-to-V transformer set to calibrate digital instrument transformer (IT) accurately at power frequency and within a wider frequency range to cover power quality aspects. The errors of the 50 A and the 200 A reference current transformer (CT) were within ±10 ppm and μrad at 50 Hz. The frequency responses of the two CTs up to 12 k… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 1 publication
0
4
0
Order By: Relevance
“…1. high current generation system (marked as red block), a set of analogue reference CTs (marked as green block) with associated precision resistors [8] and a precision 2-channel measuring system (marked as purple block) [9], [10]. The synchronization signals (marked as "Sync."…”
Section: Setup Of the Calibration System For The Ctsmentioning
confidence: 99%
See 2 more Smart Citations
“…1. high current generation system (marked as red block), a set of analogue reference CTs (marked as green block) with associated precision resistors [8] and a precision 2-channel measuring system (marked as purple block) [9], [10]. The synchronization signals (marked as "Sync."…”
Section: Setup Of the Calibration System For The Ctsmentioning
confidence: 99%
“…The rated primary currents of the C-to-V transformer set ranges from 8.3 A to 1500 A. Four commercial zero-flux CTs with rated currents of 50 A (CT50), 200 A (CT200 [8]), 600 A (CT600) and 2 kA (CT1500) were used to establish the reference CTs . To convert the different secondary currents of these CTs into a 1 V output voltage, a resistor box was built, containing six precision resistors from 1 Ω to 20 Ω.…”
Section: B the Reference C-to-v Transformermentioning
confidence: 99%
See 1 more Smart Citation
“…Study and definition of ITs errors and uncertainty contributions in the PQ phenomena measurement require that suitable systems are developed, to enable the characterization of ITs with reference waveforms representative of the actual disturbances of PQ. Starting from knowledge gathered in past projects [2]- [5], existing laboratory set-ups will be modified, extended and integrated into reference systems for the traceable calibration of current and voltage ITs, under realistic PQ phenomena. They will allow characterization of different technologies of current and voltage ITs, from the still extensively used inductive ITs to the more recent generation of Low Power Instrument Transformers (LPIT) with analog or digital output.…”
Section: Reference Measuring Systems and Test Proceduresmentioning