2020
DOI: 10.1007/s00246-020-02381-4
|View full text |Cite
|
Sign up to set email alerts
|

Serum Sirolimus Levels After Implantation of Third Generation Drug Eluting Cobalt Chromium Coronary Stent in Ductus Arteriosus in Neonates with Duct-Dependent Pulmonary Circulation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(8 citation statements)
references
References 27 publications
0
8
0
Order By: Relevance
“…In a study of neonates receiving sirolimus-eluting stents, peak sirolimus levels reached immunosuppressive levels, although no clinically significant adverse outcomes were observed. 46 The level of immunosuppression also correlates with the length and number of stents; Sivakumar et al 47 noted that sirolimus levels did not reach immunosuppressive levels if a single stent of <22 mm was used. Again, however, no clinically significant adverse outcomes were observed for the cases that did reach immunosuppressive levels, and drug levels rapidly decreased within a week.…”
Section: Type Of Stentmentioning
confidence: 99%
“…In a study of neonates receiving sirolimus-eluting stents, peak sirolimus levels reached immunosuppressive levels, although no clinically significant adverse outcomes were observed. 46 The level of immunosuppression also correlates with the length and number of stents; Sivakumar et al 47 noted that sirolimus levels did not reach immunosuppressive levels if a single stent of <22 mm was used. Again, however, no clinically significant adverse outcomes were observed for the cases that did reach immunosuppressive levels, and drug levels rapidly decreased within a week.…”
Section: Type Of Stentmentioning
confidence: 99%
“…A study using third-generation sirolimus stent demonstrated patency of the stent up to 8-16 months in univentricular lesions and 21-27 months in patients destined for biventricular repair. 9 Limitations This is a prospective study with a small sample size. There were significantly lesser number of patients than expected because of the COVID-19 pandemic and lockdowns imposed.…”
Section: Discussionmentioning
confidence: 98%
“…Another study reported the serum sirolimus levels attained in 12 neonates following ductal stenting using a third-generation cobalt chromium drug-eluting stent. 9 Their cohort involved 11 neonates with duct-dependent pulmonary circulation and one with pulmonary atresia and rhabdomyoma. The sirolimus levels were less than 5 ng/ml in patients who received a single stent or even two stents where the total length was less than 22 mm.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations