2011
DOI: 10.1016/j.talanta.2011.06.013
|View full text |Cite
|
Sign up to set email alerts
|

Sequential injection analysis implementing multiple standard additions for As speciation by liquid chromatography and atomic fluorescence spectrometry (SIA-HPLC-AFS)

Abstract: An analytical procedure for multiple standard additions of arsenic species using sequential injection analysis (SIA) is proposed for their quantification in seafood extracts. SIA presented flexibility for generating multiple specie standards at the ng mL(-1) concentration level by adding different volumes of As(III), As(V), monomethylarsonic (MMA) and dimethylarsinic (DMA) to the sample. The mixed sample plus standard solutions were delivered from SIA to fill the HPLC injection loop. Subsequently, As species w… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0
1

Year Published

2012
2012
2023
2023

Publication Types

Select...
4
3
2

Relationship

0
9

Authors

Journals

citations
Cited by 16 publications
(7 citation statements)
references
References 14 publications
0
6
0
1
Order By: Relevance
“…The As speciation was determined by HPLC‐AFS (Jitian, China) system following the method described in previous studies (Jesus et al . ; Hu et al . ).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The As speciation was determined by HPLC‐AFS (Jitian, China) system following the method described in previous studies (Jesus et al . ; Hu et al . ).…”
Section: Methodsmentioning
confidence: 99%
“…The density of the cultures, that is, OD 600 , was detected using a UV spectrophotometer (HACH DR2800, US). The As speciation was determined by HPLC-AFS (Jitian, China) system following the method described in previous studies (Jesus et al 2011;Hu et al 2012).…”
Section: Characterizations Of Different Isolates and Dynamic As(v)-rementioning
confidence: 99%
“…Extraction systems as well as the stability of the chemical species throughout the overall chemical process are also included. Jesus et al 169 propose a method for arsenic speciation by adding sequential injection analysis: SIA-HPLC-AFS. In such a system, while the chromatographic detection operates in the usual way, the SIA module is programmed to inject sequentially the standard additions of the arsenic species.…”
Section: Coupled Techniques That Use Hplc As the Separation Techniquementioning
confidence: 99%
“…3,5,[13][14][15] Results from samples with a complex matrix can be strongly affected if the differences between sample and standard matrices are neglected. Beside the external calibration, alternatives such as internal standard (IS) method [16][17][18][19] and standard addition method [20][21][22][23][24] are often used in analytical chemistry.…”
Section: Introductionmentioning
confidence: 99%