2017
DOI: 10.1016/j.talanta.2017.06.015
|View full text |Cite
|
Sign up to set email alerts
|

Sequential determination of nickel and cadmium in tobacco, molasses and refill solutions for e-cigarettes samples by molecular fluorescence

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 22 publications
(14 citation statements)
references
References 37 publications
0
14
0
Order By: Relevance
“…If metal/metalloid levels were below the limit of detection (LOD) and the study reported the original data but not the mean (SD), we replaced values below the LOD by LOD= p 2 before calculating the mean (SD) (Beauval et al 2016(Beauval et al , 2017Kamilari et al 2018;Margham et al 2016;Song et al 2018;Tayyarah and Long 2014). For studies reporting the mean (SD) for multiple groups (e.g., by nicotine levels, by different flavors) (Goniewicz et al 2014;Kamilari et al 2018;Talio et al 2015Talio et al , 2017Tayyarah and Long 2014), we calculated the weighted mean and total SD to facilitate summary and comparison across studies and device types after confirming there were no major differences across flavors and nicotine levels. The total SD was estimated because it accounts for the SD within the groups as well as among the groups (Sharma 2006).…”
Section: Metal/metalloid Data Synthesismentioning
confidence: 99%
See 2 more Smart Citations
“…If metal/metalloid levels were below the limit of detection (LOD) and the study reported the original data but not the mean (SD), we replaced values below the LOD by LOD= p 2 before calculating the mean (SD) (Beauval et al 2016(Beauval et al , 2017Kamilari et al 2018;Margham et al 2016;Song et al 2018;Tayyarah and Long 2014). For studies reporting the mean (SD) for multiple groups (e.g., by nicotine levels, by different flavors) (Goniewicz et al 2014;Kamilari et al 2018;Talio et al 2015Talio et al , 2017Tayyarah and Long 2014), we calculated the weighted mean and total SD to facilitate summary and comparison across studies and device types after confirming there were no major differences across flavors and nicotine levels. The total SD was estimated because it accounts for the SD within the groups as well as among the groups (Sharma 2006).…”
Section: Metal/metalloid Data Synthesismentioning
confidence: 99%
“…Most studies of e-liquids reported metals/metalloids in micrograms per kilogram. For easy comparison, for studies reporting e-liquid metal/metalloid levels in micrograms per liter (Beauval et al 2017;Hess et al 2017;Palazzolo et al 2017;Talio et al 2015Talio et al , 2017Zhao et al 2018) and parts per billion (ppb) (Beauval et al 2016;Dunbar et al 2018;Song et al 2018), those concentrations were converted to micrograms per kilogram, assuming the e-liquid density was 1:16 g=ml (Sleiman et al 2016). Most studies of aerosols reported metals/metalloids in ng per puff.…”
Section: Metal/metalloid Data Synthesismentioning
confidence: 99%
See 1 more Smart Citation
“…Solid phase extraction offers several advantages such as flexibility, higher enrichment factors, simplicity and safety. Moreover, previous works have demonstrated that the deposit of the coacervate on solid surface improve the limits of detection and avoids the drawbacks associated to compounds desorption [35][36][37]. Different types of solid supports were studies in the present work (Filter paper, cellulose acetate, mixed cellulose ester, Nylon and Immobilon-FL).…”
Section: Accepted Manuscriptmentioning
confidence: 99%
“…Therefore, a rapid and precise analytical method for the determination of nickel is essentially required for the production control of spoolable reinforced plastic line pipe. Numerous analytical methods were employed for the determination of nickel in different types of matrices including atomic absorption spectrometry [2,3], atomic emission spectrophotometry [4], molecular fluorescence spectroscopy [5], electroanalytical method [6] and spectrophotometry [7,8]. Spectrophotometric methods occupy special position due to their simplicity, less expensive instrumentation and high sensitivity.…”
Section: Introductionmentioning
confidence: 99%