2003
DOI: 10.1021/ac0347213
|View full text |Cite
|
Sign up to set email alerts
|

Separation of Plutonium and Neptunium Species by Capillary Electrophoresis−Inductively Coupled Plasma-Mass Spectrometry and Application to Natural Groundwater Samples

Abstract: Capillary electrophoresis (CE) was coupled to ICPMS in order to combine the good performance of this separation technique with the high sensitivity of the ICPMS for the analysis of plutonium and neptunium oxidation states. The combination of a fused-silica capillary with a MicroMist AR 30-I-FM02 nebulizer and a Cinnabar small-volume cyclonic spray chamber yielded the best separation results. With this setup, it was possible to separate a model element mixture containing neptunium (NpO2(+)), uranium (UO2(2+)), … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

8
58
0
1

Year Published

2004
2004
2021
2021

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 76 publications
(67 citation statements)
references
References 31 publications
8
58
0
1
Order By: Relevance
“…This CE-ICP-MS system allows for the separation of actinides along the CE column and detection with the ICP-MS. The limits of detection for this system were reported as 0.2 µM for a single oxidation state of an actinide [9]. While providing a limit of detection superior to UV-VIS spectroscopy, this method requires the use of expensive ICP-MS and CE systems.…”
Section: Introductionmentioning
confidence: 96%
See 1 more Smart Citation
“…This CE-ICP-MS system allows for the separation of actinides along the CE column and detection with the ICP-MS. The limits of detection for this system were reported as 0.2 µM for a single oxidation state of an actinide [9]. While providing a limit of detection superior to UV-VIS spectroscopy, this method requires the use of expensive ICP-MS and CE systems.…”
Section: Introductionmentioning
confidence: 96%
“…This method uses a tunable laser system to scan through the wavelengths of interest and the signal is detected using a piezoelectric transducer [8] [9]. This CE-ICP-MS system allows for the separation of actinides along the CE column and detection with the ICP-MS.…”
Section: Introductionmentioning
confidence: 99%
“…Cette méthode est élégante et sensible, mais elle reste tributaire du caractère fluorescent de certains éléments (uranium, terres rares, curium), elle n'est donc pas universellement applicable. Elle est concurrencée pour la spéciation par la spectrométrie de masse, de manière directe, dans une source de type électrospray [29], séparation préalable (HPLC) [30] ou élec-trophorèse capillaire [31,32] puis transfert dans la source d'un ICPMS. En ce qui concerne les méthodes mettant en oeuvre une introduction directe de l'échantillon dans la source d'un spectromètre de masse, il est possible de calculer la stabilité des espèces produites dans la source et de comparer avec les spectres de masse enregistrés.…”
Section: Spéciation En Phase Liquideunclassified
“…These include employing non-aqueous media [16,17], use of partial or complete complexation techniques [18,19], using CE in conjunction with ICP-MS [20][21][22] and use of quantitative microchip CE [23]. Despite the increased applications to inorganic materials, the applica-tion of CE in nuclear industry has been somewhat limited [24,25].…”
Section: Introductionmentioning
confidence: 99%