Separation of natural antioxidants using PDMS electrophoresis microchips coupled with amperometric detection and reverse polarity

Abstract: This report describes the use of PDMS ME coupled with amperometric detection for rapid separation of ascorbic, gallic , ferulic, p‐coumaric acids using reverse polarity. ME devices were fabricated in PDMS by soft lithography and detection was accomplished using an integrated carbon fiber working electrode aligned in the end‐channel configuration. Separation and detection parameters were investigated and the best conditions were obtained using a run buffer consisting of 5 mM phosphate buffer (pH 6.9) and a dete… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 18 publications
(10 citation statements)
references
References 66 publications
0
9
1
Order By: Relevance
“…The linear equations obtained were y = −13.71 + 1.69 x ( R = 0.998) for iodide and y = −3.07 + 0.638 x ( R = 0.996) for ascorbate, where y is the peak current (nA), x is the analyte concentration (μM), and R is the correlation coefficient. The LOD obtained for AA with the proposed Pt‐ERG electrode was lower than some previously published reports using ME‐AD and also voltammetric methods .…”
Section: Resultscontrasting
confidence: 57%
See 1 more Smart Citation
“…The linear equations obtained were y = −13.71 + 1.69 x ( R = 0.998) for iodide and y = −3.07 + 0.638 x ( R = 0.996) for ascorbate, where y is the peak current (nA), x is the analyte concentration (μM), and R is the correlation coefficient. The LOD obtained for AA with the proposed Pt‐ERG electrode was lower than some previously published reports using ME‐AD and also voltammetric methods .…”
Section: Resultscontrasting
confidence: 57%
“…When compared to conventional CE systems, ME devices offer several advantages including shorter analysis times, lower sample consumption, higher throughput capability, portability, and possibility of integrating multiple analytical steps in the same platform . Currently, ME have been largely applied in medical, pharmaceutical and forensic analysis, environmental monitoring and food quality control, coupled with a variety of detection methods, such as LIF, MS, and electrochemical modes as amperometry .…”
Section: Introductionmentioning
confidence: 99%
“…These measurements have directi mplications for the use of multiple BPE arrays for parallel, high-throughput detection schemes, such as those neededf or high bandwidth electrochemical detection in molecular separations. [25] 2. Results and Discussion 2.1.…”
Section: /4àmentioning
confidence: 99%
“…Several types of materials can be employed as electrochemical sensor and coupled to ME for amperometric detection. The most used are metallic electrodes such as platinum and gold , and carbon‐based electrodes in the form of pencil graphite lead , carbon‐ink , composite , carbon fiber , and carbon paste . In comparison with metallic electrodes, the carbon‐based sensors have advantages such as lower cost, larger availability, higher chemical stability, lower overpotential, and wider potential working range .…”