Separation of fluorescent phosphatidyl inositol phosphates by CE

Abstract: Phosphatidyl inositol 4,5-bisphosphate (PIP2) and phosphatidyl inositol 3,4,5-trisphosphate (PIP3) labeled with 4,4-difluoro-5,7-dimethyl-4-bora-3a,4a-diaza-s-indacene-3-propionic acid (BODIPY FL) on the acyl chain or a phosphatidyl ethanolamine head group were separated by CE with LIF detection. Several methods and capillary-coating procedures were tested for the separation of these phosphatidyl inositol phosphates (PIPs) at 20 degrees C. Separation of the PIPs in less than 20 min with excellent resolution wa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
24
0

Year Published

2008
2008
2023
2023

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 16 publications
(25 citation statements)
references
References 40 publications
1
24
0
Order By: Relevance
“…CE analysis of lipid analytes was performed using a custom-built CE system with laser-induced fluorescence detection as previously described 21 . Fused-silica capillaries (40 cm length, 50 μm i.d., 360 μm o.d., Polymicro Technologies, Phoenix, AZ) were used for the analyte separations.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…CE analysis of lipid analytes was performed using a custom-built CE system with laser-induced fluorescence detection as previously described 21 . Fused-silica capillaries (40 cm length, 50 μm i.d., 360 μm o.d., Polymicro Technologies, Phoenix, AZ) were used for the analyte separations.…”
Section: Methodsmentioning
confidence: 99%
“…Recently, Caliper Lifesciences employed FL-PIP 2 as a PI3K substrate for an in vitro assay in which conversion of the FL-PIP 2 to FL-PIP 3 was monitored by electrophoretic chemical separation with laser-induced fluorescence detection in a microfabricated fluidic chip. Such highly-sensitive, chemical separation techniques for monitoring phosphorylation lend themselves to cell-based assays, and several examples using capillary electrophoresis (CE) with fluorescent peptide- and lipid-based probes have been reported in single-cell biochemical measurements 2021 . However, the amphiphilic nature of PI lipids renders them to potential loss on the column during CE separation.…”
Section: Introductionmentioning
confidence: 99%
“…46 The efficiency and resolution of the separation of SphFl and SphFl-1-P were similar to those of other CE separations of lipids. [47][48][49] …”
mentioning
confidence: 99%
“…CE with indirect UV detection was used to determine lysophosphatidic acids, anionic phospholipids and phospholipid classes [13][14][15][16][17]. CE with fluorescence detection was used to study cardiolipin, phosphatidylserine and sphingolipids [18][19][20][21][22][23]. CE in conjunction with MS was used to analyze phosphatidylethanol, lyso-glycerophosphocholine and other phospholipids [9,12,24].…”
Section: Introductionmentioning