2007
DOI: 10.1524/ract.2007.95.11.629
|View full text |Cite
|
Sign up to set email alerts
|

Separation of actinides by extraction chromatography prior to X-ray fluorescence measurement for analytical control of a PUREX test

Abstract: Five separation methods by Eichrom column extraction chromatography were developed and implemented for performance control of a PUREX (Plutonium, Uranium Refining by EXtraction) test.Four of them, concerning the separation between actinides, are described in this work. The latest, concerning the separation of actinides from fission products in a main raffinate is described in another article submitted to the same journal.For the production of U, Pu and Np streams following the “main extraction” step in the PUR… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2008
2008
2018
2018

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 4 publications
0
2
0
Order By: Relevance
“…Each sub-samples (~10 g) were ashed in 400 °C for about 5 h. Then, radioactive tracers ( 242 Pu, 232 U, 229 Th, 239 Np, 243 Am, 85 Sr) and stable nickel (as a tracer for 63 Ni analyses) were added, all determined by weight using analytical balance. 239 Np as an isotope with short half live time (2.36 d) [ 5 ] was milked from 243 Am generator and spiked to the samples directly before digestion [ 6 ]. The same activity of 239 Np that was added to the samples was also kept for comparative measurement in order to estimate radiochemical recovery of the used method (by gamma spectrometry) and to check purity of obtained tracer (by mass spectrometry).…”
Section: Methodsmentioning
confidence: 99%
“…Each sub-samples (~10 g) were ashed in 400 °C for about 5 h. Then, radioactive tracers ( 242 Pu, 232 U, 229 Th, 239 Np, 243 Am, 85 Sr) and stable nickel (as a tracer for 63 Ni analyses) were added, all determined by weight using analytical balance. 239 Np as an isotope with short half live time (2.36 d) [ 5 ] was milked from 243 Am generator and spiked to the samples directly before digestion [ 6 ]. The same activity of 239 Np that was added to the samples was also kept for comparative measurement in order to estimate radiochemical recovery of the used method (by gamma spectrometry) and to check purity of obtained tracer (by mass spectrometry).…”
Section: Methodsmentioning
confidence: 99%
“…1.144 ± 0.057 g/mL 1.154 ± 0.058 g/mL Weighing a: Because spectral interference, a selelective separation of U in a main Pu flow [7] was need. analysis protocols and to guarantee that the quantities implemented are sufficient for the intended analytical techniques.…”
Section: Initial High-activity Analysesmentioning
confidence: 99%