2004
DOI: 10.1039/b400598h
|View full text |Cite
|
Sign up to set email alerts
|

Separation of actinides at ultra-trace level from urine matrix using extraction chromatography-inductively coupled plasma mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
27
1

Year Published

2005
2005
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 54 publications
(29 citation statements)
references
References 30 publications
1
27
1
Order By: Relevance
“…On-line extraction chromatographic separation of actinides, including 241 Am, from urine matrices coupled with ICP-QMS has also been evaluated (Hang et al, 2004). 308 Detection limits of 0.15 pg mL À1 (0.02 Bq mL À1 ) were reported for a 25 mL urine sample volume. Coupling of ow injection analysis with ICP-SFMS has also been reported for the analysis of environmental samples, with detection limits down to 0.6 fg being reported.…”
Section: Americium-241mentioning
confidence: 99%
“…On-line extraction chromatographic separation of actinides, including 241 Am, from urine matrices coupled with ICP-QMS has also been evaluated (Hang et al, 2004). 308 Detection limits of 0.15 pg mL À1 (0.02 Bq mL À1 ) were reported for a 25 mL urine sample volume. Coupling of ow injection analysis with ICP-SFMS has also been reported for the analysis of environmental samples, with detection limits down to 0.6 fg being reported.…”
Section: Americium-241mentioning
confidence: 99%
“…ICPMS is a popular mass spectrometric technique to determine concentrations and isotope ratios of Am and other actinide elements (Agarande et al, ; Truscott et al, ; Boulyga et al, ; Lee et al, ; Hang et al, ; Pointurier, Baglan, & Hemet, ; Wang, Chen, & Chiu, ; Epov et al, ; Lee et al, ; Varga, ; Varga et al, ,; Zheng & Yamada, ; Guerin et al, ; Krachler et al, ). In ICP, the M + ions are produced with generation of plasma (with Ar gas) at atmospheric pressure, and introduction of the sample into the spray chamber with a pneumatic nebulizer.…”
Section: Different Mass Spectrometric Techniques Used For Am and Its mentioning
confidence: 99%
“…241 Am along with other actinides (Np, U, Pu, and Th) was determined in urine samples, for bioassay, with on‐line coupling the extraction chromatography column to a Q‐ICPMS (Hang et al, ). The TRU extractant resin, which consists of carbamoylmethylphosphine oxide (CMPO) dissolved in tri‐n‐butyl phosphate (TBP), was used as a stationary phase.…”
Section: Applications Of Various Mass Spectrometric Techniques For Stmentioning
confidence: 99%
“…Hang et al using TRU Resin to separate actinides, but this work lacked the selectivity needed to measure actinides at ultra trace levels in urine, due to overlapping of actinide peaks [6] . Epov at al reported an automated preconcentration system using TRU Resin, but indicated that the separation of uranium 4 from plutonium was not complete [7] .…”
Section: Introductionmentioning