Sensorless Control Technique for PWM Rectifiers With Voltage Disturbance Rejection and Adaptive Power Factor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
46
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 50 publications
(47 citation statements)
references
References 32 publications
1
46
0
Order By: Relevance
“…As shown in (12), the accuracy of state estimation is affected by the magnitude of ξ(·), and hence depends on the performance of the proposed UIE. Since fast and accurate estimation of d e (·) is provided by the UIE according to Theorem 1, quick convergence of ξ(t) → 0 is guaranteed.…”
Section: Closed-loop Analysismentioning
confidence: 99%
See 2 more Smart Citations
“…As shown in (12), the accuracy of state estimation is affected by the magnitude of ξ(·), and hence depends on the performance of the proposed UIE. Since fast and accurate estimation of d e (·) is provided by the UIE according to Theorem 1, quick convergence of ξ(t) → 0 is guaranteed.…”
Section: Closed-loop Analysismentioning
confidence: 99%
“…A common practice is to maximize the inherited robustness of a controller by careful parameter design and tuning [5], [6]. Further robustness improvement can be achieved via advanced techniques such as nonlinear control [7]- [9], H ∞ or optimized loop-shaping robust control [10]- [12], and adaptive intelligent control [13], [14]. A more attractive approach distinguished from the aforementioned comes with the concept of unknown-input estimation, which brings disturbance rejection to a higher level, as demonstrated by various industrial applications [15]- [22].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…And then, the vector control method based on virtual flux oriented is widely used to the power grid voltage sensorless control scheme of threephase PWM rectifier. But, in the conventional virtual fluxlinkage observer, there exists a pure integral link, and then the estimation process of virtual power grid flux-linkage is inevitably affected by the initial value and the cumulative deviation of the integrator [2,[20][21][22][23]. In order to overcome the deficiencies of pure integrator, a first-order low-pass filter is adopted to replace the pure integrator; the initial value problem of pure integrator can be successfully solved [13]; however, the problem of amplitude and phase deviation is caused.…”
Section: Introductionmentioning
confidence: 99%
“…VSR has a serious of characteristics, such as input current being sine wave, operation in unity power factor, and bidirectional flow of power [1]. Then, some industrial fields, such as industrial frequency converter have put an urgent need for the PWM rectifier technology [2][3]. Three-phase power grid is often in unbalanced station [2].…”
Section: Introductionmentioning
confidence: 99%