Direct Power Control Strategy of PWM Rectifier Based on Improved Virtual Flux-Linkage Observer

Abstract: In order to achieve the low cost and high performance control of three-phase PWM rectifier, a direct power control (DPC) strategy based on a new-style virtual flux-linkage observer is proposed. The model of three-phase PWM rectifier and the principle of virtual flux-linkage vector control are introduced firstly. Then, in order to avoid the effect of integral initial value and cumulative deviation, three first-order low-pass filters are cascaded to replace the pure integral link; an improved virtual flux-linkag… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(9 citation statements)
references
References 21 publications
0
9
0
Order By: Relevance
“…So the system output (controlled variable) "U dc " can be controlled by the input current. Hence the transfer function of the plant can be obtained by taking the ratio as shown in Equation (11).…”
Section: Design Of the Pi Controllermentioning
confidence: 99%
See 2 more Smart Citations
“…So the system output (controlled variable) "U dc " can be controlled by the input current. Hence the transfer function of the plant can be obtained by taking the ratio as shown in Equation (11).…”
Section: Design Of the Pi Controllermentioning
confidence: 99%
“…The estimations performed using this method are found to be accurate even during the nonideal grid conditions like unbalanced and distorted phase voltages. The dynamic performance of the flux estimation technique is improved using two cascaded second‐order LPF 10 and third‐order LPF 11 . On the counter side, the use of higher‐order LPF increases the complexity of the tuning process.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Direct power control without line voltage sensors is investigated. This sensorless method is based on definition and estimation virtual flux ,The three-phase rectifier can be seen as a virtual AC motor, its virtual flux-linkage can be used to estimate the voltage of rectifier , in the conventional virtual flux (VF) estimation of three-phase rectifier,But in the conventional (VF) estimation, there exists a pure integral link, and then the estimation process of (VF) is automatically affected by the initial value and the cumulative deviation of the integrator [11][12][13][14][15][16][17]. For solving pure integration problems, more researchers are focusing on replacing the pure integrator by using low-pass filters (LPFs), in which case the pure integrator initial value problem can be solved with success [11], [15][16][17] but, the problem of amplitude and phase deviation is caused.…”
Section: Introductionmentioning
confidence: 99%
“…For solving pure integration problems, more researchers are focusing on replacing the pure integrator by using low-pass filters (LPFs), in which case the pure integrator initial value problem can be solved with success [11], [15][16][17] but, the problem of amplitude and phase deviation is caused. In order to dominate the influence of its problems, several authors propose methods of estimation of the (VF)], diverse authors propose technique of estimation of the (VF) such as [12], [18]. In summary, the key to a successful operation of the DPC utilizing grid (VF) estimation is dependent on the effectiveness of the (VF) estimation procedure and the selection of the converter switching states [19].…”
Section: Introductionmentioning
confidence: 99%