2020
DOI: 10.1016/j.optmat.2020.110123
|View full text |Cite
|
Sign up to set email alerts
|

Sensitivity enhancement of SPR biosensors employing heterostructure of PtSe2 and 2D materials

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
37
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 102 publications
(37 citation statements)
references
References 45 publications
0
37
0
Order By: Relevance
“… film placed on prism coupler, RI of prism is . The third layer is platinum-di-selenide , RI of is deliberated as and coating thickness of [ 31 ]. The fourth layer is graphene, RI of the graphene layer is deliberated as and coating thickness of , where is the number of graphene layers [ 23 ].…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“… film placed on prism coupler, RI of prism is . The third layer is platinum-di-selenide , RI of is deliberated as and coating thickness of [ 31 ]. The fourth layer is graphene, RI of the graphene layer is deliberated as and coating thickness of , where is the number of graphene layers [ 23 ].…”
Section: Methodsmentioning
confidence: 99%
“…Finally, the proficiency of the SPR sensors is categorized on the basis of sensitivity ( S ), full width at half maximum (FWHM), DA, FOM, SNR, and QF parameters [ 31 , 63 ].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…SPR sensors are in the trends globally due to a variety of applications in the different areas like biosensing, monitoring of the environment, medical field, food and safety, gas detection, temperature analysis, pressure measurement, concentration analysis of the fluid, analyze different components of the blood, and as well as real-time observation of the molecular interaction of the molecules in the microbiology and biochemistry with ultra-high sensitivity, and level free detection. It has applications in optical fields like optical modulators and plasma detectors [5]- [8]. Various sensors using SPR technology have been proposed, but researchers, academicians, and scientists are putting their efforts into improving the sensor's performance [9], [10].…”
Section: Introductionmentioning
confidence: 99%
“…The metal layer of silver (Ag) is regularly used in the conventional biosensor; sometimes, gold (Au) is preferred [5]. This material shows a sharp dip in the resonance curve near the infrared region and near-infrared region, i.e., it reflects that the sensor produces high sensitivity due to sharp dip.…”
Section: Introductionmentioning
confidence: 99%