Sensitivity Analysis to Operation Margin of Zone 3 Impedance Relays With Bus Power and Shunt Susceptance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
16
0

Year Published

2009
2009
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 25 publications
(16 citation statements)
references
References 8 publications
0
16
0
Order By: Relevance
“…Eight given fault resistances Rf (f = 1, ..., 8) are selected and the comparison is shown in Figure 10. Iac/dc_ (1,2,3,4)(Rf) is the fundamental frequency current or DC current calculation result obtained by the expressions for three-phase, two-phase, single-phase, and none-phase circulating states, respectively. …”
Section: Analysis Of Fault Process Under Arbitrary Fault Resistancementioning
confidence: 99%
See 1 more Smart Citation
“…Eight given fault resistances Rf (f = 1, ..., 8) are selected and the comparison is shown in Figure 10. Iac/dc_ (1,2,3,4)(Rf) is the fundamental frequency current or DC current calculation result obtained by the expressions for three-phase, two-phase, single-phase, and none-phase circulating states, respectively. …”
Section: Analysis Of Fault Process Under Arbitrary Fault Resistancementioning
confidence: 99%
“…The backup protection setting calculation, which has to take protection coordination into consideration, is the most complicated and time-consuming part. Studies on backup protection setting calculation have been maturing with the expansion of AC power grids over the last few decades [1][2][3][4][5].…”
Section: Introductionmentioning
confidence: 99%
“…In this paper, the method proposed in [16] is adopted here to calculate the sensitivity of apparent impedance to the change of electrical parameters, such as bus voltages and bus powers. Based on sensitivity information, a load shedding algorithm is proposed here executed by the CC agent.…”
Section: Sensitivity Based Load Shedding Strategymentioning
confidence: 99%
“…, is the sensitivity of relay operation margin to load power at bus n. So if we assume emergent load shedding on the loads in this paper have the same step size, which is represented by a percentage α (| | < 1), then the amount of LS at this moment will be obtained by (16). Assume that the power flowing into the bus is positive, the shedding amount ∆ is positive, the load powers and α will be negative.…”
Section: Sensitivity Based Load Shedding Strategymentioning
confidence: 99%