Sensitive square-wave voltammetric determination of tadalafil (Cialis®) in pharmaceutical samples using a cathodically pretreated boron-doped diamond electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 44 publications
(14 citation statements)
references
References 34 publications
0
14
0
Order By: Relevance
“…On reviewing literature, TMS was quantified by several methods, namely; TLC [16][17][18], HPLC in different matrices [18][19][20][21], capillary electrophoresis [16], spectrophotometry [16,[22][23][24], and electrochemical methods [16,25]. For TAD, several methods were reported for its determination includ-ing TLC [26][27][28][29], HPLC [26,[30][31][32][33][34][35][36], gas chromatography [26,37], capillary electrophoresis [26], spectrophotometry [26,[38][39][40][41], and electrochemical methods [42][43][44].…”
Section: Introductionmentioning
confidence: 99%
“…On reviewing literature, TMS was quantified by several methods, namely; TLC [16][17][18], HPLC in different matrices [18][19][20][21], capillary electrophoresis [16], spectrophotometry [16,[22][23][24], and electrochemical methods [16,25]. For TAD, several methods were reported for its determination includ-ing TLC [26][27][28][29], HPLC [26,[30][31][32][33][34][35][36], gas chromatography [26,37], capillary electrophoresis [26], spectrophotometry [26,[38][39][40][41], and electrochemical methods [42][43][44].…”
Section: Introductionmentioning
confidence: 99%
“…However, the linearly range obtained for TDL in the proposed BIA method was one of the higher in comparison to other voltammetric methods. As a proof of the concept, the obtained linearly range in the BIA‐AD with the cathodically pretreated BDD was around 120‐fold times higher in comparison to the same electrode at a stationary voltammetric cell (SWV detection) , endorsing the capability of hydrodynamic systems to minimize the working electrode poisoning (reduced time of contact between the fouling agent and sensor) . The proposed BIA methods are more versatile (can be used for qualitative investigation of TDL purity and TDL determination), more simple (does not require complex procedures for electrode modification) and presents the highest analytical frequency (270 injections per hour) in comparison to other reported EM for TDL, a result of the very fast hydrodynamic mass transport (BIA) and instantaneous oxidation of TDL over the H‐BDD surface (AD).…”
Section: Resultsmentioning
confidence: 99%
“…In this scenario, electroanalytical methods (EM) are attractive, once they present simplicity, sensitivity, low consumption of reagents, relative low cost, and portable instruments. Few EM were reported in literature for TDL determination in pharmaceutical products, using pulsed voltammetric detection under stationary conditions at unmodified [15] and modified carbon electrodes [16,[17][18][19]. Furthermore, any of such works aims the screening of TDL (only for determination in authentic pharmaceutics for quality control purposes).…”
Section: Introductionmentioning
confidence: 99%
“…Tadalafil (TDL) is used for treating benign prostatic hyperplasia. This pharmaceutical was quantified by Sartori and coauthors using SWV methodology . The authors used BR buffer (pH 4) on BDD electrodes (doping level of 8000 ppm).…”
Section: Electroanalysis Of Pharmaceuticalsmentioning