2006
DOI: 10.1097/00007691-200608000-00002
|View full text |Cite
|
Sign up to set email alerts
|

Sensitive, High Throughput HPLC-MS/MS Method With On-line Sample Clean-up for Everolimus Measurement

Abstract: A new HPLC-MS/MS method for everolimus measurement was developed that includes the following features: small sample volume, short run time, fast, simple and cost-efficient sample preparation, assessment of performance of two internal standards (IS), SDZ RAD 223-756 and ascomycin and comparison of the method with an HPLC-MS/MS reference method. The authors established a multiple reaction monitoring positive ion HPLC-MS/MS method with on-line extraction and sample cleanup. This procedure includes: an API 2000 tr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
19
0

Year Published

2007
2007
2017
2017

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 38 publications
(20 citation statements)
references
References 29 publications
1
19
0
Order By: Relevance
“…Several LC-MS/MS methods have been published for the quantitation of individual [16][17][18][19][20] or multiple immunosuppressants [21][22][23] in whole blood. Our laboratory initially introduced a previously published LC-MS/MS method for the analysis of sirolimus [20], which has subsequently been modified to also allow the additional simultaneous quantitation of tacrolimus and everolimus.…”
Section: Immunosuppressant Concentrations Measured By Lc-ms/ms Pagementioning
confidence: 99%
“…Several LC-MS/MS methods have been published for the quantitation of individual [16][17][18][19][20] or multiple immunosuppressants [21][22][23] in whole blood. Our laboratory initially introduced a previously published LC-MS/MS method for the analysis of sirolimus [20], which has subsequently been modified to also allow the additional simultaneous quantitation of tacrolimus and everolimus.…”
Section: Immunosuppressant Concentrations Measured By Lc-ms/ms Pagementioning
confidence: 99%
“…589 The sensitivity and selectivity provided by MS helped to ease sample preparation in clinical chemistry laboratories. Column-switching systems coupling the extraction support to the chromatographic column before MS detection were also used for the analysis of sirolimus [598][599][600][601][602][603][604][605][606][607][608][609][610][611] and everolimus 598,599,602,603,[605][606][607]609,[612][613][614] in whole blood. LLE 615 or SPE 616 on 96-well plates constitutes another approach for sample preparation automatisation.…”
Section: Mtor Inhibitorsmentioning
confidence: 99%
“…One transition per analyte was regarded to be sufficient, since only few substances can be ionized in negative mode using APCI and since the masses of the analytes are quite high, therefore interferences with other compounds are unlikely. Also in most other methods published, only one transition per analyte is monitored [10,11,16].…”
Section: Lc-ms/ms Analysismentioning
confidence: 99%
“…doi:10.1016/j.jchromb.2010.02.029 [9][10][11]. Within the last 10 years, several online extraction procedures have been published [12][13][14][15][16][17][18][19][20][21][22][23]. Most of them use either online solid-phase extraction (SPE) or an additional chromatographic column for extraction.…”
Section: Introductionmentioning
confidence: 99%