2009
DOI: 10.1016/j.aca.2009.03.044
|View full text |Cite
|
Sign up to set email alerts
|

Sensitive determination of triazines in underground waters using stir bar sorptive extraction directly coupled to automated thermal desorption and gas chromatography–mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
29
0
2

Year Published

2009
2009
2016
2016

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 68 publications
(31 citation statements)
references
References 30 publications
0
29
0
2
Order By: Relevance
“…galaxolide, EHMC, helvetolide, cyfluyhrins, musk ambrette, benzo[g,h,i]perylene, etc.) [30]. This was more noticeable when the highest amount of salt (200 g L À1 ) was added, especially for those non-polar compounds showing highest molecular weights (log K ow > 6) such as PAHs with a high Table 1 Retention times (Rt), log octanol water partition coefficients (K ow ), accurate masses of selected ions in GC-APGC-ToF-MS, method detection limits (MDL), instrumental detection limits (IDL), calibration curves, and coefficients of determination (R 2 ) for target compounds.…”
Section: Other Sbse Parametersmentioning
confidence: 99%
“…galaxolide, EHMC, helvetolide, cyfluyhrins, musk ambrette, benzo[g,h,i]perylene, etc.) [30]. This was more noticeable when the highest amount of salt (200 g L À1 ) was added, especially for those non-polar compounds showing highest molecular weights (log K ow > 6) such as PAHs with a high Table 1 Retention times (Rt), log octanol water partition coefficients (K ow ), accurate masses of selected ions in GC-APGC-ToF-MS, method detection limits (MDL), instrumental detection limits (IDL), calibration curves, and coefficients of determination (R 2 ) for target compounds.…”
Section: Other Sbse Parametersmentioning
confidence: 99%
“…이에 따라 EU에서는 아트라진과 시마진의 사용 을 전면 금지하였고, 사용량도 50,000 kg/year로 규제하는 등(6,7) 농약에 대한 안전 관리 방안을 강화하는 추세이며, 미국 EPA에 서도 어류와 수생 식물을 대상으로 독성 및 잔류시험을 실시한 결과를 통해 농약에 대한 위험도를 알리고 있다 (8). 또한, 인접 국가 중국의 경우에도 트리아진계 제초제에 대한 식물의 피해를 제시하여 광합성 억제 등을 통한 먹이사슬 문제도 언급하고 있 다 (7,9 …”
unclassified
“…The current trend is to develop simple, miniature, automatic, high selectivity and recovery sample pretreatment techniques in order to achieve the trace level pollutant analysis. Solid phase extraction (SPE) [2][3][4], solid phase microextraction (SPME) [5][6][7], liquid-phase microextraction (LPME) [8][9][10], stir bar sorptive extraction (SBSE) [11,12] and cloud point extraction (CPE) [13,14] are new methods which have been used for the separation and preconcentration of diverse analytes and have solved some of the problems mentioned above of conventional techniques. Nevertheless, some drawbacks still exist for these techniques.…”
Section: Introductionmentioning
confidence: 99%