2015
DOI: 10.1016/j.microc.2015.01.012
|View full text |Cite
|
Sign up to set email alerts
|

Sensitive detection of bisphenol A in complex samples by in-column molecularly imprinted solid-phase extraction coupled with capillary electrophoresis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
19
0
1

Year Published

2015
2015
2022
2022

Publication Types

Select...
8
1
1

Relationship

1
9

Authors

Journals

citations
Cited by 81 publications
(20 citation statements)
references
References 34 publications
0
19
0
1
Order By: Relevance
“…Table 3 Comparison of proposed method with those of other methods. 4 Liquid chromatography-fluorescence detection; 5 Ultrasonic assisted extraction; 6 Gas chromatography-mass spectrometry; 7 Cloud-point extraction; 8 Liquid chromatography; 9 Solid-phase extraction; 10 Liquid chromatographytandem mass spectrometry; 11 Dispersive liquid-liquid microextraction; 12 High-performance liquid chromatography; 13 Enzyme-linked immunosorbent assay; 14 Solid phase microextraction; 15 Liquid phase microextraction; 16 Stir bar sorptive extraction.…”
Section: Analytical Applicationsmentioning
confidence: 99%
“…Table 3 Comparison of proposed method with those of other methods. 4 Liquid chromatography-fluorescence detection; 5 Ultrasonic assisted extraction; 6 Gas chromatography-mass spectrometry; 7 Cloud-point extraction; 8 Liquid chromatography; 9 Solid-phase extraction; 10 Liquid chromatographytandem mass spectrometry; 11 Dispersive liquid-liquid microextraction; 12 High-performance liquid chromatography; 13 Enzyme-linked immunosorbent assay; 14 Solid phase microextraction; 15 Liquid phase microextraction; 16 Stir bar sorptive extraction.…”
Section: Analytical Applicationsmentioning
confidence: 99%
“…To monitor the environmental levels, behaviors and fate of BPA, many methods, such as capillary electrophoresis [ 11 ], gas chromatography coupled with mass spectrometry (GC-MS) [ 12 ], high performance liquid chromatography mass spectrometry (HPLC-MS) [ 13 ], enzyme linked immune sorbent assay (ELISA) [ 14 ], electrochemical methods [ 15 , 16 ], etc., have been developed. Combined with pretreatment procedures of solid-phase extraction [ 17 ], liquid-liquid extraction [ 18 ] and immunoaffinity chromatography [ 19 ], GC-MS, HPLC-MS and ELISA can be used for selectively and sensitively determining BPA in complex matrices [ 20 , 21 ].…”
Section: Introductionmentioning
confidence: 99%
“…For monitoring the pollution levels and ecological risks of BPA, many methods based on capillary electrophoresis [9][10][11], gas chromatography coupled with mass spectrometry (GC-MS) [12][13][14][15], high performance liquid chromatography mass spectrometry (LC-MS) [16,17], enzyme linked immune sorbent assay (ELISA) [18][19][20], and electrochemical methods [21][22][23][24] have been developed. Pretreatment procedures, such as solid-phase extraction [24][25][26], liquid-liquid extraction [27,28], and immunoaffinity chromatography [29,30], are often involved when using GC-MS, HPLC-MS, and ELISA for analyzing BPA in complex matrices [31,32].…”
Section: Introductionmentioning
confidence: 99%