2018
DOI: 10.3390/app8122535
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Bisphenol A in Beverages by an Electrochemical Sensor Based on Rh2O3/Reduced Graphene Oxide Composites

Abstract: A novel electrochemical sensor, based on a Rh2O3–reduced graphene oxide (rGO) composite modified carbon electrode, has been developed for detecting bisphenol A (BPA) in beverages. The prepared Rh2O3/rGO and its precursor materials were characterized by scanning electron microscope (SEM) and X-ray diffraction (XRD). Under optimum conditions, the sensor presented good electrochemical performance for analyzing BPA, with a linear range of 0.6–40 μM, detection limit of 0.12 μM, good reproducibility, and excellent s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 16 publications
(5 citation statements)
references
References 48 publications
0
5
0
Order By: Relevance
“…Next, 0.5 g of the pieces was put into 100 mL of ethanol for 2 h under ultrasonication. Finally, the supernatant was taken as a sample of thermal paper …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Next, 0.5 g of the pieces was put into 100 mL of ethanol for 2 h under ultrasonication. Finally, the supernatant was taken as a sample of thermal paper …”
Section: Methodsmentioning
confidence: 99%
“…Finally, the supernatant was taken as a sample of thermal paper. 37 ■ RESULTS AND DISCUSSION Characterizations. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were adopted to characterize the morphology and structural features of the representative product.…”
Section: ■ Experimental Sectionmentioning
confidence: 99%
“…Figure 3 shows CVs of Fe3O4-CPE in PBS pH 7 without (a) and with PBA 10 ppm at scan rate of 0.1 V/s. nanoparticles directly reduced at the electrode surface according to the following reaction [1] :…”
Section: Electrochemical Sensing Of Bpamentioning
confidence: 99%
“…(a) (b) Figure 3: CV voltammograms of CPE (N. 0) and Fe3O4-CPEs in PBS pH 7 without (a) and with PBA 10 ppm (b) at scan rate of 0.1 V/s (vs Ag/AgCl) Fe3O4(s)+2e − +6H + (aq) → 2Fe 2+ (aq)+3H2O+FeO(s) (1) Then, Fe 2+ ions produced could combine with phosphate ions in the PBS solution:…”
Section: Electrochemical Sensing Of Bpamentioning
confidence: 99%
See 1 more Smart Citation