2020
DOI: 10.1002/elan.201900756
|View full text |Cite
|
Sign up to set email alerts
|

Sensitive Anodic Stripping Voltammetric Copper Ions Determination Performed in Double Deposition and Double Stripping Steps System for Real Water Samples Analysis

Abstract: The article reports on utilization of double deposition and stripping steps for increasing sensitivity of Cu(II) determination by anodic stripping voltammetry (ASV) at two lead film working electrodes. A significant preconcentration of copper was achieved thanks to utilization of a simple design of four electrodes system that gives possibility to perform one measurement cycle consisting of two deposition and two stripping steps. Due to the fact that deposition step is doubled, the concentration of Pb(II) neede… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
5
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
2

Relationship

2
0

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 39 publications
(42 reference statements)
0
5
0
Order By: Relevance
“…lowering the detection limit of analytical procedures as compared to the values obtained in a traditional three electrodes system [39–49];…”
Section: Standard Measurement Procedures Using Double Deposition/accu...mentioning
confidence: 94%
See 3 more Smart Citations
“…lowering the detection limit of analytical procedures as compared to the values obtained in a traditional three electrodes system [39–49];…”
Section: Standard Measurement Procedures Using Double Deposition/accu...mentioning
confidence: 94%
“…(i) lowering the detection limit of analytical procedures as compared to the values obtained in a traditional three electrodes system [39][40][41][42][43][44][45][46][47][48][49]; (ii) an increase of determinations selectivity thanks to the appropriate selection of the first deposition/accumulation conditions and/or the first stripping potential from the first working electrode [42,43,45,46].…”
Section: Standard Measurement Procedures Using Double Deposition/accu...mentioning
confidence: 99%
See 2 more Smart Citations
“…In the present article, a new anodic stripping voltammetric procedure for Bi 3 + quantification based on utilization of double deposition and stripping step system presented before [12][13][14][15][16] is described. The present work is an interesting example of the possibility of elimination of copper interferences based on a simple instrumental solution by appropriate selection of the first stripping step conditions.…”
mentioning
confidence: 99%