2011
DOI: 10.1039/c0sc00610f
|View full text |Cite
|
Sign up to set email alerts
|

Self-referenced RGB colour imaging of intracellular oxygen

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
95
0
3

Year Published

2012
2012
2023
2023

Publication Types

Select...
9
1

Relationship

3
7

Authors

Journals

citations
Cited by 99 publications
(98 citation statements)
references
References 23 publications
0
95
0
3
Order By: Relevance
“…Such an approach has been described for dye encapsulation, for example in silicate or polystyrene spheres but the advantage of this approach is that the probes are physically separated between core and shell of the nanoparticle, which can reduce potential probe cross-talk. 67 While lectine binding experiments provide a conceptional proof for selective binding, in vitro cellular binding of the nanoparticles was investigated in CHO cells. Carbohydrate receptors such as lectins are prevalent on cell surfaces, and CHO-K1 was used in the present study because this cell line has been demonstrated previously to express relatively large amounts of Galectin 1, which resides at the plasma membrane and can bind to extracellular glycoconjugate ligands.…”
Section: ■ Results and Discussionmentioning
confidence: 99%
“…Such an approach has been described for dye encapsulation, for example in silicate or polystyrene spheres but the advantage of this approach is that the probes are physically separated between core and shell of the nanoparticle, which can reduce potential probe cross-talk. 67 While lectine binding experiments provide a conceptional proof for selective binding, in vitro cellular binding of the nanoparticles was investigated in CHO cells. Carbohydrate receptors such as lectins are prevalent on cell surfaces, and CHO-K1 was used in the present study because this cell line has been demonstrated previously to express relatively large amounts of Galectin 1, which resides at the plasma membrane and can bind to extracellular glycoconjugate ligands.…”
Section: ■ Results and Discussionmentioning
confidence: 99%
“…Fluorescent nanosensors are composed of a porous biofriendly polymeric matrix, such as polyacrylamide, 54 silica sol-gel, 52 polystyrene derivatives, 55 and poly(methyl methacrylate), 56 and usually present with dimensions that are less than pulled optical fibers, but greater than free fluorophores. The large surface area of the nanosensor permits a small volume of sensing elements to interact with a large number of analytes.…”
Section: Polymeric Fluorescent Nanosensorsmentioning
confidence: 99%
“…As the signal intensities in a well are affected by the experimental -in particular coating -conditions, the intact peptide was used as a reference signal to obtain ratiometric measurements that are essentially independent of absolute signal intensities. 25,26 The ratio of the signal aer renin incubation to the reference signal thus denes the degree of proteolytic degradation.…”
Section: Renin Assaymentioning
confidence: 99%