2013
DOI: 10.2478/molim-2012-0003
|View full text |Cite
|
Sign up to set email alerts
|

Selective sorption of uric acid by novel molecularly imprinted polymers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 20 publications
0
5
0
Order By: Relevance
“…UA is characterized by polyfunctional interactions with synthetic and natural polymers [14]. In this study, we used as initial matrices (CPs) copolymers with different extents of hydrophobicity, prepared at HEMA to EGMD ratios of 50 : 50 and 80 : 20 (Table 1).…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…UA is characterized by polyfunctional interactions with synthetic and natural polymers [14]. In this study, we used as initial matrices (CPs) copolymers with different extents of hydrophobicity, prepared at HEMA to EGMD ratios of 50 : 50 and 80 : 20 (Table 1).…”
Section: Resultsmentioning
confidence: 99%
“…Previously we synthesized network polymers with UA molecular imprints from ethylene glycol dimethacrylate (EGDM) and 2-dimethylaminoethyl methacrylate (DMAEMA) [7]. It is known that the use of ionic sorbents for operation with blood plasma is undesirable [8].…”
Section: Macromolecular Compounds and Polymeric Materialsmentioning
confidence: 99%
See 1 more Smart Citation
“…However, electrochemical techniques are more preferable in this context because of their ease of handling, cost-effectiveness, and higher accuracy level to avoid any false positive signaling. Electrochemical techniques like DPV, chronoamperometry (CA), square-wave voltammetry (SWV) are powerful tools among others to carry out sensing of UA at the physiological concentration level by modifying the bare electrode with polymers (ethylene glycol, dimethacrylate, (dimethylamino)­ethyl methacrylate, etc.) and biomaterials , (norepinephrine, propionylcholine, etc.).…”
Section: Introductionmentioning
confidence: 99%
“…Since the sensors involving use of enzymes are expensive and time taking, it becomes necessary to have a cost effective method for the determination of UA in biological fluids. For fabrication of selective electrode, material with selective recognition properties can be obtained by molecular imprinting technology 24.…”
Section: Introductionmentioning
confidence: 99%