2012
DOI: 10.1039/c2an36075f
|View full text |Cite
|
Sign up to set email alerts
|

Selective determination of cholesterol based on cholesterol oxidase-alkaline phosphatase bienzyme electrode

Abstract: A bienzyme electrode for the determination of cholesterol was prepared by the co-immobilization of cholesterol oxidase and alkaline phosphatase (ALP) on the carbon nanotubes modified electrode surface. The parameters influenced the performance of the bienzyme electrode such as the pH of the base solution; the concentration of DPP and the incubation time, were optimized. A linear calibration graph in the 0.05-2.0 mM concentration range with the sensitivity of 4.65 μA mM(-1) was obtained. In addition, this work … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(8 citation statements)
references
References 48 publications
0
8
0
Order By: Relevance
“…[110] When ALP is placed in a solution containing disodium phenyl phosphate, it produces phenol, which is electroactive. For the dual enzyme electrode, hydrogen peroxide produced by ChOx in the presence of cholesterol, decreased the sensitivity of the electrode for phenol, and produced a lower electrode response with DPV.…”
Section: 0 Enzyme Substratesmentioning
confidence: 99%
“…[110] When ALP is placed in a solution containing disodium phenyl phosphate, it produces phenol, which is electroactive. For the dual enzyme electrode, hydrogen peroxide produced by ChOx in the presence of cholesterol, decreased the sensitivity of the electrode for phenol, and produced a lower electrode response with DPV.…”
Section: 0 Enzyme Substratesmentioning
confidence: 99%
“…It also shows high affinity for proteins and availability of reactive functional groups for chemical modifications which make it a perfect enzyme immobilization support [33]. Transducers have been fabricated using nano ZnO film on chitosan [34], Pt-Pd NPs-CS-GS nanocomposite [35], CNT-CS/GCE [36]. Along with conducting polymers non conducting matrices are suitable for enzyme immobilization.…”
Section: Organic and Inorganic Matrices Based Biosensorsmentioning
confidence: 99%
“…Phenol is produced by the action of ALP. Then oxidation of phenol is interpreted for cholesterol determination [36].…”
Section: Nano Structures Based Biosensorsmentioning
confidence: 99%
“…Multi-target systems can be developed by co-immobilization ( Orrego et al, 2020 ) and have aroused interest due to their different applications, which include screening of ligands ( Chen et al, 2017 ; Wu et al, 2020 ), syntheses of products ( Betancor and Luckarift, 2010 ), design of biocatalyst cascades ( Kang et al, 2014 ), and construction of biosensors to detect diseases ( Zhang et al, 2012 ).…”
Section: Introductionmentioning
confidence: 99%