2018
DOI: 10.1007/s11630-018-1034-z
|View full text |Cite
|
Sign up to set email alerts
|

Selection of the Relevant Turbulence Model in a CFD Simulation of a Flow Disturbed by Hydraulic Elbow — Comparative Analysis of the Simulation with Measurements Results Obtained by the Ultrasonic Flowmeter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
6
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 2 publications
0
6
0
Order By: Relevance
“…Consequently, it is recommended to conduct research that allows for the investigation of the influence of obstructions (knees, gate valves, constrictions, and throttles) on ultrasonic flow-meter readings. Previous studies [15][16][17] have addressed the issue of ultrasonic flow measurement under non-standard measurement settings downstream of a pipeline elbow. This study focused on the data acquired downstream of a butterfly valve with a manual closing angle.…”
Section: Introductionmentioning
confidence: 99%
“…Consequently, it is recommended to conduct research that allows for the investigation of the influence of obstructions (knees, gate valves, constrictions, and throttles) on ultrasonic flow-meter readings. Previous studies [15][16][17] have addressed the issue of ultrasonic flow measurement under non-standard measurement settings downstream of a pipeline elbow. This study focused on the data acquired downstream of a butterfly valve with a manual closing angle.…”
Section: Introductionmentioning
confidence: 99%
“…In this case, the measuring accuracy of the devices should be as high as possible, assuming the lowest possible investment costs. That is why in each case of measurement, the most important factor is the selection of the best available measurement technique in relation to costs [ 7 , 8 , 9 ]. Performing flow measurements is characterized by a multitude of solutions, such as Pitot tubes, measuring orifices, turbine flow meters, bend flow meters, vortex flow meters, Coriolis flow meters, electromagnetic flow meters and ultrasonic flow meters [ 10 , 11 , 12 , 13 , 14 ].…”
Section: Introductionmentioning
confidence: 99%
“…Achieving device accuracy below 1% of the measured value is only possible for multi-way flow meters [4]. An important condition for maintaining the declared accuracy of measurement is the installation of the flow meter heads while maintaining the straight pipe sections required in the standards [5].…”
Section: Introductionmentioning
confidence: 99%