DOI: 10.1046/j.1469-0705.2000.00268.x
|View full text |Cite
|
Sign up to set email alerts
|

Segmentary fetal branch pulmonary artery blood flow velocimetry: in utero Doppler study

Abstract: The data obtained suggests that pulmonary circulation maintains stable vascular resistance during gestation in the human fetus. However, the PI obtained from the separate segments of the branch pulmonary artery is unique and each differs from the other, reflecting the proximity to the heart and the peripheral impedance at each location.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2001
2001
2014
2014

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 20 publications
(10 citation statements)
references
References 11 publications
0
10
0
Order By: Relevance
“…22,23 These studies established that at least 3 levels of bifurcation of pulmonary vessels were imaged in normal fetuses, leading us to consider this simple morphologic criterion for evaluating pulmonary arterial vasculature in fetuses with CDH.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…22,23 These studies established that at least 3 levels of bifurcation of pulmonary vessels were imaged in normal fetuses, leading us to consider this simple morphologic criterion for evaluating pulmonary arterial vasculature in fetuses with CDH.…”
Section: Discussionmentioning
confidence: 99%
“…The level of the section was chosen to obtain the largest possible cross-sectional image of the lung. The power Doppler angiogram was considered normal when the 3 distinct segments of the pulmonary vasculature 22,23 were clearly identified, that is, when at least 3 levels of bifurcation of the pulmonary vessels were imaged ( Figure 1A). The pulmonary angiogram was otherwise considered poor ( Figure 1, B and C) or absent ( Figure 1D).…”
Section: Methodsmentioning
confidence: 99%
“…With the advent of high‐resolution ultrasound technology, coupled with sophisticated Doppler and power Doppler angiography, it is now possible to evaluate fetal arterial62 and venous systems63. We therefore adopted Clements and Warner's classification system with modifications, based on 2D and Doppler ultrasound, and applied it to fetal findings.…”
Section: A Unified Concept For Congenital Lung Malformation and Its Cmentioning
confidence: 99%
“…By contrast, the proximal branch is clearly identified, and it can be insonated at a consistent location with small angles on virtually all occasions. Furthermore, reference values throughout gestation are available for the parameters used in this study22, 31 and this allows the use of Z ‐scores for gestational age21, 32.…”
Section: Discussionmentioning
confidence: 99%