2021
DOI: 10.1007/s41365-021-00983-y
|View full text |Cite
|
Sign up to set email alerts
|

Screener3D: a gaseous time projection chamber for ultra-low radioactive material screening

Abstract: In experiments searching for rare signals, background events from the detector itself are some of the major factors limiting search sensitivity. Screening for ultra-low radioactive detector materials is becoming ever more essential. We propose to develop a gaseous time projection chamber (TPC) with a Micromegas readout for radio screening. The TPC records three-dimensional trajectories of charged particles emitted from a flat sample placed in the active volume of the detector. The detector can distinguish the … Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 32 publications
0
6
0
Order By: Relevance
“…During the development of this work, a similar concept has been proposed in [25] and [26]. In [25] a dedicated conceptual design and MonteCarlo simulations including the detector response are presented, while in [26] some experimental data are shown.…”
Section: Jinst 17 P08035mentioning
confidence: 99%
“…During the development of this work, a similar concept has been proposed in [25] and [26]. In [25] a dedicated conceptual design and MonteCarlo simulations including the detector response are presented, while in [26] some experimental data are shown.…”
Section: Jinst 17 P08035mentioning
confidence: 99%
“…The counting efficiency is calculated based on simulation and cross-validated with a commercial silicon detector. A dedicated simulation program based on GEANT4 has been developed to study the detector response [13,25]. In addition to the 241 Am calibration source, we also measured a copper sample intentionally contaminated with alpha radioactivities.…”
Section: Counting Efficiencymentioning
confidence: 99%
“…Therefore, those events tend to have short tracks. Similar to what we have reported in [13], we have used a fiducial cut with a fiducial distance from the inner surface of the field cage larger than 27 mm, an angle cut to select upward-going tracks, and a nHits≥10 cut to suppress background.…”
Section: Background Suppression With Tracksmentioning
confidence: 99%
See 2 more Smart Citations