2000
DOI: 10.1016/s0003-2670(00)00757-1
|View full text |Cite
|
Sign up to set email alerts
|

Scheme for collinear ionization in supersonic jet/multiphoton ionization/time-of-flight mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
21
0

Year Published

2000
2000
2022
2022

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 28 publications
(23 citation statements)
references
References 7 publications
1
21
0
Order By: Relevance
“…The jet-expansion is sampled anywhere between 15-25 mm downstream of the pulsed valve, just behind the sudden-freeze surface of the jet expansion, where the molecule density is still relatively high. Further reduction in the distance to ionization has been documented by Onoda et al [12]. In this arrangement, the jet is expanded collinear with the axis of ion flight, shown in Figure 1c.…”
supporting
confidence: 56%
See 1 more Smart Citation
“…The jet-expansion is sampled anywhere between 15-25 mm downstream of the pulsed valve, just behind the sudden-freeze surface of the jet expansion, where the molecule density is still relatively high. Further reduction in the distance to ionization has been documented by Onoda et al [12]. In this arrangement, the jet is expanded collinear with the axis of ion flight, shown in Figure 1c.…”
supporting
confidence: 56%
“…The unskimmed jet is ionized roughly 2.5 cm downstream of the nozzle orifice. (c) Collinear ionization scheme as reported by Onoda et al [12]. This method uses a line beam focus configuration for increased ionization volume, which is located roughly 1 cm downstream of the unskimmed jet.…”
Section: Laser Systemsmentioning
confidence: 99%
“…The technique described herein is essentially based on proximity ionization, which is a technique for ionizing an analyte behind the nozzle for expansion of the molecule into a vacuum. 10 This approach increases the density of the analyte molecule in the ionization region, thereby improving the ionization efficiency. A variety of electrode assemblies were made and evaluated for optimizing the ion trajectory using the SIMION software.…”
Section: Introductionmentioning
confidence: 99%
“…The basic principle has been reported elsewhere, and is only briefly described here. 10 The sample gas at a specified concentration is generated using a standard gas generator (Gastec, Permeater). The sample gas is introduced from a pulsed nozzle into a vacuum for mass spectrometry.…”
Section: Introductionmentioning
confidence: 99%
“…The principles of operation of SSJ/REMPI/TOF-MS and SRS have been described previously. [11][12][13] The second-harmonic emission of an optical parametric oscillator (Spectra-Physics, MOPO-730, 1 mJ, 6 ns, 0.2 cm -1 ) is focused by a lens into a Raman cell filled with hydrogen. The two-color beam generated by SRS is focused into a jet.…”
mentioning
confidence: 99%