Scattered radiation during fixation of hip fractures-is distance alone enough protection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
26
1

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(29 citation statements)
references
References 12 publications
2
26
1
Order By: Relevance
“…18 Despite their limitations, film badges have been employed successfully in the majority of contemporary studies in this field and remain the 'gold standard for personal radiation monitoring in hospitals'. 17 No consistent exposure level was detected with the radiographers' film badges which concurs with work by Alonso et al 18 who showed that for hip fracture fixation, the scattered dose outside a 2-m zone is less than 1 µSv. Although they question the necessity of personal lead protection outside this area, they do recommend that lead aprons and thyroid shields be worn by surgeon and assistants.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…18 Despite their limitations, film badges have been employed successfully in the majority of contemporary studies in this field and remain the 'gold standard for personal radiation monitoring in hospitals'. 17 No consistent exposure level was detected with the radiographers' film badges which concurs with work by Alonso et al 18 who showed that for hip fracture fixation, the scattered dose outside a 2-m zone is less than 1 µSv. Although they question the necessity of personal lead protection outside this area, they do recommend that lead aprons and thyroid shields be worn by surgeon and assistants.…”
Section: Discussionmentioning
confidence: 99%
“…6,7 The range of operative procedures requiring image intensifier screening has led to an interest by orthopaedic surgeons in their exposure to ionising radiation. [8][9][10][11] Studies have considered exposure during experimental operation set-ups on phantom patients, 12 during common trauma operations, [13][14][15] for different locations and personnel in the operating theatre, [16][17][18] for different parts of the body, 19 and also investigating methods to reduce exposure. 20,21 There is evidence, however, that actual practice of basic ionising radiation protection varies widely.…”
mentioning
confidence: 99%
“…Alonso et al, [17] concluded that the scatter radiation outside 2 meter zone of a C Arm unit is less than 1 mSv [Table/ Fig-7]. Within 2 metre of the C Arm unit, the lead protection is a must.…”
Section: A Personal Protectionmentioning
confidence: 99%
“…[Table/ Fig-7]: Zone of Scatter radiation is at the back of the X-ray tube: Alonso et al, [17] concluded that the scatter radiation outside 2 meter zone of a C Arm unit is less than 1 mSv c. Maintenance of equipment and protective shieldsi. A decrease in efficiency of the C Arm unit is compensated by increased exposure to get similar brightness and contrast of imaging.…”
Section: Equipment Related Factorsmentioning
confidence: 99%
“…During fluoroscopy, the surgeon is exposed to either primary or scatter radiation due to the necessary proximity to the fluoroscope. The assistant surgeon, nurses, and anaesthetists are better protected against radiation from the fluoroscope because they can distance themselves from the fluoroscope when it radiates, thus the exposure is reduced to nearly immeasurable values; but also due to staff rotations, such that the assistant surgeons and nurses do not assist all of the PAO procedures, their exposures are limited [2,14,17,18].…”
Section: Introductionmentioning
confidence: 99%